Hi,

I need use CT sensor SCT-013 20A/1V .. can i use this CT ? if I can I need know CurrentGain constant for this sensor. I will measure AC 0-3A.

Sorry for my English but speak in another languages in not my strong part :D

Thanks !

@CircuitSetup
Copy link
Owner

Sorry for not replying sooner.

Yes, you can use this CT. However you will need to sever the jumper on the back of the board so the on-board burden resistor is not used. The CT has its own burden resistor since the output is measured in volts.