Device-specific Caveats

Synway SMG4000 Series

  • Only SMPP v3.4 is implemented.

  • enquire_link need to be invoked every 0.5 seconds.

  • Firmware versions before 09/25/2020, deliver_sm - dest_addr field returns garbage.

  • The use of bind_receiver and bind_transmitter is not supported.

DBLTek GoIP Series

  • Only SMPP v3.4 is implemented.

  • enquire_link need to be invoked every 0.5 seconds.

  • System ID pattern
    e.q: if set goip then every slot is goip01 ... goip48,
    but if use goip login, then use all slots sent sms.

  • Multipart SMS, Only support TLV 0424, 4.8.4.36 message_payload

  • Only supports some Command IDs:

    bind_receiver
    bind_transmitter
    bind_transceiver
    submit_sm
    deliver_sm
    enquire_link