jgroehl commented Aug 13, 2024

Describe the bug

The test AbsorptionAndScatteringWithinHomogenousMedium is currently failing.
It is supposed to test that the far-field diffusion approximation holds by running two MCX simulations with low absorption and high scattering with different anisotropy/scattering value pairs.

The result should be looking as follows: at the source (in the near field), the simulations are expected to drastically differ, but towards the edges of the simulation volume, the simulations are expected to look more and more similar (excluding random effects).

Currently, this is not the case.

Also: The entire documentation for the test is incorrect.