Many HomeKit sensors have the same configurable options. The common sensors are defined here along with their available options.
Type | Device Type |
---|---|
5 | Contact Sensor |
6 | Occupancy Sensor |
7 | Leak Sensor |
8 | Smoke Sensor |
9 | Carbon Monoxide Sensor |
10 | Carbon Dioxide Sensor |
11 | Filter Change Sensor |
12 | Motion Sensor |
The following configuration is available for sensors:
Section | Key | Description |
---|---|---|
Actions | "a" | The actions performed by the accessory |
State & Status Inputs | "f[n]" & "g[n]" | Inputs that manage accessory state |
Wildcard Actions | "y[n]" | Perform an action when an accessory reaches a target value |
Accessory Notifications | "m" | Notifications to send to another accessory |
Initial State | "s" | State a switch accessory enters on boot |
{
"c": { "l": 13},
"a": [
"t": 12,
"i": 10,
"0": { "r": [{ "g": 16, "v": 0 }] },
"1": { "r": [{ "g": 16, "v": 1 }] },
"f1": [{ "g": 14 }]
}]
}
This is an example of a Sonoff Basic unit with a motion sensor ("t": 12
)
connected to GPIO 14 ("f1": [{ "g": 14 }]
) and an LED connected to GPIO 13
("l": 13
).
The motion sensor accessory ("t": 12
) causes
action "1"
to be performed when activated ("f1"
). 10 seconds later
action "0"
will be performed because of the inching time option ("i": 10
)
NOTE: The following options are not needed in this example as they are the
default options but are included to make the example more readable:
"t": 1
& "v": 0
A sensor has two actions.
Action | State | Description |
---|---|---|
"0" | Deactivated | This action should be performed when sensor is deactivated. This is the default action on boot. |
"1" | Activated | This action should be performed when sensor is activated |
The Digital Outputs
"r": [{}]
for each should be configured to attain the desired state.
The list of notifications "m"
supported by a sensor are as follows:
Value | Notification |
---|---|
0 | Sensor DEACTIVATED (default) |
1 | Sensor ACTIVATED |
See the general Accessory Notifications section for details of how to configure these notifications.
State inputs "f[n]"
& Status Inputs "g[n]"
are supported by this accessory.
The supported list is:
Key | Action |
---|---|
"f0" | Perform action "0" (Deactivate) |
"f1" | Perform action "1" (Activate) |
"g0" | Set accessory state to Deactivated |
"g1" | Set accessory state to Activated |
Refer to State Inputs for more detail and examples.
ICMP Ping inputs "p[n]"
and "q[n]"
are supported by this accessory.
The supported list is:
Key | Action |
---|---|
"p0" | Perform action "0" (Deactivate) |
"p1" | Perform action "1" (Activate) |
"q0" | Set accessory state to Deactivated |
"q1" | Set accessory state to Activated |
Refer to ICMP Ping Inputs for more detail.
Wildcard Actions "y[n]"
are supported by this accessory.
The supported list is:
Key | Action |
---|
Refer to Wildcard Actions for more detail.
The Initial State key is not supported by this accessory. Refer to Initial State for more details.
Home Accessory Architect
Home Accessory
Installation
Setup Mode
HAA Home Manager App
Configuration
About
General
| GPIOs Configuration
Accessory
| Actions
Service Types
Air Quality
Battery
Data History
Fan
Free Monitor
Garage Door
HAA iAirZoning
Heater Cooler
Humidifier
Light Sensor
Lightbulb
Lock Mechanism
Sensors
Power Measure
Security System
Stateless Button & Doorbell
Switch & Outlet
Temperature & Humidity
TV
Water Valve
Window Covering