Notifications
You must be signed in to change notification settings - Fork 10
/
scd30-service.py
executable file
·341 lines (287 loc) · 9.98 KB
/
scd30-service.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
#!/usr/bin/env python
# coding=utf-8
#
# Copyright © 2018 UnravelTEC
# Michael Maier <michael.maier+github@unraveltec.com>
#
# This program is free software: you can redistribute it and/or modify
# it under the terms of the GNU General Public License as published by
# the Free Software Foundation, either version 3 of the License, or
# (at your option) any later version.
#
# This program is distributed in the hope that it will be useful,
# but WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
# GNU General Public License for more details.
#
# You should have received a copy of the GNU General Public License
# along with this program. If not, see <https://www.gnu.org/licenses/>.
#
# If you want to relicense this code under another license, please contact info+github@unraveltec.com.
# hints from https://www.raspberrypi.org/forums/viewtopic.php?p=600515#p600515
from __future__ import print_function
# This module uses the services of the C pigpio library. pigpio must be running on the Pi(s) whose GPIO are to be manipulated.
# cmd ref: http://abyz.me.uk/rpi/pigpio/python.html#i2c_write_byte_data
import pigpio # aptitude install python-pigpio
import time
import struct
import sys
import math
import crcmod # aptitude install python-crcmod
import os, signal
from subprocess import call
def eprint(*args, **kwargs):
print(*args, file=sys.stderr, **kwargs)
sys.stderr.flush()
def flprint(*args, **kwargs):
print(*args, **kwargs)
sys.stdout.flush()
SENSOR_FOLDER = '/run/sensors/'
SENSOR_NAME = 'scd30'
LOGFILE = SENSOR_FOLDER + SENSOR_NAME + '/last'
PRESSURE_SENSORS = ['bme280', 'bme680']
MEAS_INTERVAL = 2 # integer between 1 and 255 (if longer needed, change code below)
PIGPIO_HOST = '127.0.0.1'
I2C_SLAVE = 0x61
I2C_BUS = 1
DEBUG = True
DEBUG = False
def exit_gracefully(a,b):
flprint("exiting gracefully...")
stop_measurement()
flprint("measurement stopped")
os.path.isfile(LOGFILE) and os.access(LOGFILE, os.W_OK) and os.remove(LOGFILE)
flprint("sensor value files cleared")
pi.i2c_close(h)
flprint("i2c handle closed, exit 0")
exit(0)
def exit_hard():
flprint("exiting hard...")
reset()
flprint("resetted")
os.path.isfile(LOGFILE) and os.access(LOGFILE, os.W_OK) and os.remove(LOGFILE)
flprint("sensor value files cleared")
pi.i2c_close(h)
flprint("i2c handle closed, exit 1")
exit(1)
signal.signal(signal.SIGINT, exit_gracefully)
signal.signal(signal.SIGTERM, exit_gracefully)
deviceOnI2C = call("i2cdetect -y 1 0x61 0x61|grep '\--' -q", shell=True) # grep exits 0 if match found
if deviceOnI2C:
flprint("I2Cdetect found " + SENSOR_NAME)
else:
flprint(SENSOR_NAME + " (0x61) not found on I2C bus")
exit(1)
pi = pigpio.pi(PIGPIO_HOST)
if not pi.connected:
flprint("no connection to pigpio daemon at " + PIGPIO_HOST + ".")
exit(1)
try:
pi.i2c_close(0)
except:
if sys.exc_value and str(sys.exc_value) != "'unknown handle'":
eprint("Unknown error: ", sys.exc_type, ":", sys.exc_value)
try:
h = pi.i2c_open(I2C_BUS, I2C_SLAVE)
except:
eprint("i2c open failed") and sys.stdout.flush()
exit(1)
flprint("connected to pigpio daemon at " + PIGPIO_HOST + ".")
f_crc8 = crcmod.mkCrcFun(0x131, 0xFF, False, 0x00)
def calcCRC(TwoBdataArray):
byteData = ''.join(chr(x) for x in TwoBdataArray)
return f_crc8(byteData)
def calcFloat(sixBArray):
struct_float = struct.pack('>BBBB', sixBArray[0], sixBArray[1], sixBArray[3], sixBArray[4])
float_values = struct.unpack('>f', struct_float)
first = float_values[0]
return first
def read_n_bytes(n):
try:
(count, data) = pi.i2c_read_device(h, n)
except:
eprint("error: i2c_read failed")
exit(1)
if count == n:
DEBUG and flprint("read_n_bytes(" + str(n) + ") successful")
if n % 3 == 0:
DEBUG and flprint("multiple of 3 bytes read, calc checksum")
for i in range(int(n / 3)):
offset = i * 3
sent_crc = data[offset + 2]
calc_crc = calcCRC([data[offset + 0], data[offset + 1]])
if sent_crc == calc_crc:
DEBUG and flprint(str(i) + ": crc " + hex(sent_crc) + " of " + hex(data[offset + 0]) + hex(data[offset + 1]) + " OK")
else:
eprint(str(i) + ": crc " + hex(sent_crc) + " of " + hex(data[offset + 0]) + hex(data[offset + 1]) + " NOK, should be " + hex(calc_crc))
return False
return data
else:
eprint("error: read bytes didnt return " + str(n) + " B, but " + str(count) + " B")
return False
# takes an array of bytes (integer-array)
def i2cWrite(data):
try:
pi.i2c_write_device(h, data)
except:
eprint("error: i2c_write failed")
return -1
return True
def read_firmware_version():
ret = i2cWrite([0xD1,0x00])
if ret == True:
firmware_version = read_n_bytes(3)
if firmware_version != False:
flprint("firmware version: " + hex(firmware_version[0]) + hex(firmware_version[1]))
return True
eprint("firmware version could not be read")
return False
def read_meas_interval():
ret = i2cWrite([0x46, 0x00])
if ret == -1:
eprint("error: read measurement interval unsuccessful")
return -1
ret = read_n_bytes(3)
if ret != False:
interval = ret[0] * 256 + ret[1]
flprint("current measurement interval: " + str(interval))
return interval
eprint("error: read measurement interval didnt return 3B")
return -1
def read_asc_status():
ret = i2cWrite([0x53,0x06])
if ret == -1:
return -1
data = read_n_bytes(3)
if data == False:
flprint("read asc unsuccessful")
return -1
DEBUG and flprint("answer: " + hex(data[0]) + " " + hex(data[1]) + " " + hex(data[2]) + ".")
if data[1] == 1:
flprint("asc enabled")
return 1
if data[1] == 0:
flprint("asc disabled")
return 0
flprint("asc status unknown")
return -1
def stop_measurement():
ret = i2cWrite([0x01, 0x04])
if ret == -1:
eprint("error: sending stop measurement command unsuccessful")
def reset():
flprint("reset")
ret = i2cWrite([0xD3,0x04])
if ret == -1:
flprint("reset unsuccessful")
return
time.sleep(0.5)
def get_pressure(last_pressure):
for sensor in PRESSURE_SENSORS:
pressure_mbar = last_pressure
pressure_filename = SENSOR_FOLDER + sensor + '/last'
current_pressure = 0
if os.path.isfile(pressure_filename):
pressure_file = open(pressure_filename,'r')
DEBUG and flprint("read from " + pressure_filename)
for line in pressure_file:
if line.startswith('pressure_hPa'):
line_array = line.split()
# print(line_array)
if len(line_array) > 1:
float_val = float(line_array[1])
if(isinstance(float_val,float)):
current_pressure = int(float_val)
if current_pressure > 300:
DEBUG and flprint("got pressure from " + pressure_filename)
break
if current_pressure > 300:
if last_pressure != current_pressure:
flprint('pressure compensation changed from', last_pressure, 'to', current_pressure)
pressure_mbar = current_pressure
break
return pressure_mbar
def start_cont_measurement(pressure_mbar):
LSB = 0xFF & pressure_mbar
MSB = 0xFF & (pressure_mbar >> 8)
ret = i2cWrite([0x00, 0x10, MSB, LSB, calcCRC([MSB,LSB])])
if ret == -1:
print("start_cont_measurement unsuccessful")
exit_hard()
print('started cont measurement with ' + str(pressure_mbar) + 'mbar')
read_meas_result = read_meas_interval()
if read_meas_result != MEAS_INTERVAL:
# if not every default, set it
flprint("setting interval to " + str(MEAS_INTERVAL))
ret = i2cWrite([0x46, 0x00, 0x00, MEAS_INTERVAL, calcCRC([0x00, MEAS_INTERVAL])])
if ret == -1:
exit_hard()
read_meas_result = read_meas_interval()
if read_meas_result != MEAS_INTERVAL:
eprint("setting measurement interval unsuccessful, returned " + str(read_meas_result))
exit_hard()
asc_status = read_asc_status()
if asc_status == 0:
#activating ASC
flprint("enabling asc...")
i2cWrite([0x53, 0x06, 0x00, 0x01, calcCRC([0x00,0x01])])
time.sleep(MEAS_INTERVAL+1)
asc_status = read_asc_status()
call(["mkdir", "-p", SENSOR_FOLDER + SENSOR_NAME])
pressure_mbar = 972 # 300 metres above sea level
last_pressure = pressure_mbar
start_cont_measurement(last_pressure)
log_once = True
while True:
new_pressure = get_pressure(last_pressure)
if new_pressure != last_pressure:
start_cont_measurement(new_pressure)
last_pressure = new_pressure
# read ready status
deadmancounter = 20 * MEAS_INTERVAL
attempts = deadmancounter
while True:
if deadmancounter == 0:
flprint(str(attempts) + " attempts to get data unsuccessful, exiting")
exit_hard()
ret = i2cWrite([0x02, 0x02])
if ret == -1:
exit_hard()
data = read_n_bytes(3)
if data == False:
flprint("read data ready unsuccessful")
time.sleep(0.1)
deadmancounter -= 1
continue
if data[1] == 1:
#print "data ready"
break
else:
#eprint(".")
time.sleep(0.1)
deadmancounter -= 1
#read measurement
i2cWrite([0x03, 0x00])
data = read_n_bytes(18)
if data == False:
flprint("read data unsuccessful")
time.sleep(MEAS_INTERVAL)
continue
float_co2 = calcFloat(data[0:5])
float_T = calcFloat(data[6:11])
float_rH = calcFloat(data[12:17])
if log_once:
flprint("CO₂: " + str(float_co2) + ", rH: " + str(float_rH) + ", T: " + str(float_T))
log_once = False
if math.isnan(float_co2) or math.isnan(float_rH) or math.isnan(float_T) or float_co2 <= 0.0 or float_rH <= 0.0:
flprint("read wrong, co2: " + str(float_co2) + ", rH: " + str(float_rH) + ", T: " + str(float_T))
log_once = True
continue
output_string = 'gas_ppm{{sensor="SCD30",gas="CO2"}} {0:.8f}\n'.format( float_co2 )
output_string += 'temperature_degC{{sensor="SCD30"}} {0:.8f}\n'.format( float_T )
output_string += 'humidity_rel_percent{{sensor="SCD30"}} {0:.8f}\n'.format( float_rH )
logfilehandle = open(LOGFILE, "w",1)
logfilehandle.write(output_string)
logfilehandle.close()
time.sleep(-0.1 + MEAS_INTERVAL)
pi.i2c_close(h)