To reinstall ESXi

  • maintenance mode
  • remove from DVS
  • remove from inventory
  • shut down
  • stick USB in; turn on
  • F11 for boot menau
  • boot off USB
  • set root password
  • F2 to configure
    • set IPv4 to static not DHCP
    • set IPv6 static
    • enable ESXi shell
    • enable ssh
  • add esxi host to cluster; set recommended image if appropriate
  • add esxi host to DVS
  • set NTP Time configuration
  • Licensing → Assign License
  • Storage → Add software adapter
    • Dynamic Discovery → Add: 10.9.9.80 → Rescan Storage
  • Rename local datastore datastore1SSD-1
  • VMkernel adapters → vmk0:
    • vMotion
    • Provisioning
    • Management
  • PCI Devices: toggle passthrough for NVIDIA

Getting Rid of Fan Warnings

  • On ESXi: Host hardware fan status
  • On BMC (baseboard management controller) (most of these seem to be about FANB):
Lower Critical - going low - Assertion
Lower Non-recoverable - going low - Assertion
Lower Non-recoverable - going low - Deassertion
Lower Critical - going low - Deassertion

Let's download Supermicro's IPMICFG. They have an ESXi version! Unzip & copy over to ESXi. Then install. The --no-sig-check avoids the dreaded "Could not find a trusted signer: self-signed certificate" error:

esxcli software vib install --viburl file:///IPMICFG_1.35.2_build.240627_ESXi_8x.vib --no-sig-check

After the necessary reboot, try the following:

/opt/supermicro/ipmicfg/IPMICFG.esxi -help
/opt/supermicro/ipmicfg/IPMICFG.esxi -fan 1 # set from "optimal" to "full"

To configure Supermicro X10SDV-8C-TLN4f+

Two BIOS Versions:

ESXi Host esxi-0.nono.io esxi-1.nono.io
Version 1.2 1.3
Date 04/21/2017 02/13/2018

No need to change the BIOS settings—the defaults are fine.

Follow these instructions to create a bootable USB key.

Press F11 during boot to get to the boot menu. Make sure to boot from the UEFI version of the USB key.

On the console: press F2 to "customize system".

  • Configure Management Network
    • IPv6 Configuration
      • Set static IPv6 address and network Configuration
        • Static address #1: 2601:646:100:69f0::29/64
    • DNS Configuration
      • Use the following DNS server addresses and hostname
        • Hostname: esxi-1.nono.io
  • Apply changes and restart management network? Y
  • Test Management Network
  • Troubleshooting Options
    • Enable ESXi Shell
    • Enable SSH
  • ESC

Add the ESXi Host to the Cluster:

  • Log into the vCenter
  • Right-click on the cluster
  • Select "Add Hosts..."
    • Add Hosts: IP address or FQDN: esxi-1.nono.io Username: root Password: xxx

Fix System logs are stored on non-persistent storage

[This lengthy process may be unnecessary; try rebooting the ESXi host to see if the message returns; if it does, follow the procedure below]

KB Article.

The fix is to set the scratch location to non-persistent storage. First, determine the GUID, the real directory, that the symbolic link of datastore SSD-1 points to, i.e.:

ssh esxi-1 ls -l /vmfs/volumes/SSD-1
  1. Browse to the host in the vSphere Web Client navigator.
  2. Click the Manage tab, then click Settings.
  3. Under System, click Advanced System Settings.
  4. Set ScratchConfig.ConfiguredScratchLocation to /vmfs/volumes/5be7ada3-5d63c00d-9974-ac1f6bac3394/.locker.

reboot the ESXi host & make sure that ScratchConfig.ConfiguredScratchLocation is on persistent storage.

Set up NTP Client

  • Select esxi-1.nono.io
    • Configure → System → Services
      • Time Configuration → Edit Use Network Time Protocol (Enable NTP client) NTP Servers: time.google.com NTP Service Status: Start NTP Service NTP Service Startup Policy: Start and stop with host

Add iSCSI

  • Hosts & Clusters → esxi-1.nono.io → Configure → Storage → Storage Adapters
    • Click + Add Software Adapter, select Add software iSCSI adapter, click OK
    • Select the newly-created iSCSI Software Adapter; notice the panel below
    • Click on the Dynamic Discovery tab
    • Click + Add...
      • iSCSI Server: 10.0.9.80 (use IP address because sometimes there are DNS outages); click OK
    • When you see the alert Due to recent configuration changes, a rescan of "vmhba64" is recommended., click Rescan Adapter
    • Click on Devices, you should see FreeNAS iSCSI Disk(naa.65....)

You don't need to mount it; it's just there.

Create DVS

  • Networking
    • right-click on Datacenter → Distributed Switch → New Distributed Switch...
      • Name: dvs
      • Location: dc
      • Select version: 7.0.0 - ESXi 7.0 and later
      • checked: Default port group
      • Port group name: nono; click Finish

Add Host to DVS (Distributed Virtual Switch)

  • Networking
    • DVS → Right Click
      • Add and Manage Hosts... Add Hosts Select Hosts
        • ➕ New Hosts... esxi-1.nono.io
        • Manage Physical Adapters vmnic3 Assign Uplink
        • Manage VMkernel adapters vmk0 Assign Port Group nono

Set up iSCSI Storage

Add iSCSI from vCenter:

  • Select Host
    • Configure
      • Storage → Storage Adapters
        • ➕ Add Software Adapter Add software iSCSI adapter
        • Select the newly-added iSCSI adapter (vmhba64)
          • Dynamic Discovery → Add iSCSI server: 10.0.9.80 (use IP address, not hostname) (force IPv4 binding?)
          • Network Port Binding ➕ Add... nono (dvs)
        • Rescan Adapter
          • Devices Make sure the iSCSI disk appears, "FreeNAS iSCSI disk"

Set up vMotion

  • Select esxi-1.nono.io
    • Configure → Networking → VMkernel Adapters
      • Select vmk0 Edit vMotion

vMotion Benchmarks

These benchmarks were obtained by vMotion'ing a VCSA, 10 GB RAM allotted, 2.2 GB used, between 2 ESXi hosts. We changed compute resource only. We scheduled vMotion with high priority.


11 s, 18 s, 14 s, 20 s, 12 s, 19s (curiously, esxi-0 to esxi-1 takes between 11-14 seconds, but the other direction takes 18-20 seconds)

Swap ports on the QNAP? See if the QNAP is the problem?

12 s, 17 s (it's not the QNAP)

Cables? Probably esxi-1's cables, because when it's transmitting the data that's when it's slower.

13 s, 18 s

It's not the cables. Maybe the time is off?

ssh esxi-0 date & ssh esxi-1 date
Mon Nov 12 01:22:24 UTC 2018
Mon Nov 12 01:22:24 UTC 2018

Maybe it's esxi-0's cables. 13s, 19s

You know what? I no longer care.

on 1Gbe: 97s, 95s, 97s, 95s, 94s, 95s


To find an ESXi's mac address:

esxcfg-nics -l
esxcfg-vswitch -l
esxcfg-vmknic -l

SSD Performance on Skull Canyon ESXi is really lame:

Total disk usage (in MB/s) (over the last hour) (of which bonnie++ was running for 35 minutes):

  • Avg: 1.71
  • Max: 7.91
  • Latest: 2.04

Remember to always do this:

export TERM=xterm

Using esxtop to troubleshoot:

 4:41:21pm up 6 days 19:12, 483 worlds, 3 VMs, 5 vCPUs; CPU load average: 0.01, 0.01, 0.01

 ADAPTR PATH                 NPTH AQLEN   CMDS/s  READS/s WRITES/s MBREAD/s MBWRTN/s DAVG/cmd KAVG/cmd GAVG/cmd QAVG/cmd DAVG/rd KAVG/rd GAVG/rd QAVG/rd DAVG/wr KAVG/wr GAVG/w
 vmhba0 -                       1    31    11.30     0.99     7.93     0.00     1.92   300.66  1796.42  2097.08     0.05    0.15    0.02    0.17    0.00  313.38   90.25  403.6
vmhba32 -                       1     1     0.00     0.00     0.00     0.00     0.00     0.00     0.00     0.00     0.00    0.00    0.00    0.00    0.00    0.00    0.00    0.0

Snapshot taken while bonnie++ was running on VM.

[root@esxi:/var/log] df -h
Filesystem   Size   Used Available Use% Mounted on
VMFS-6     978.0G  36.1G    941.9G   4% /vmfs/volumes/ssd
vfat       249.7M   8.0K    249.7M   0% /vmfs/volumes/3071f4ed-73fd8718-f003-4b4f069e050b
vfat       285.8M 205.8M     80.0M  72% /vmfs/volumes/58688336-3e239f00-8dbc-001fc69c1ddf
vfat       249.7M 143.6M    106.1M  58% /vmfs/volumes/cdb18eec-f0051e03-18a7-8bc932eca2d5

Let's try setting the ScratchC

  • ScratchConfig.ConfiguredScratchLocation: /vmfs/volumes/ssd/.locker
  • ScratchConfig.CurrentScratchLocation: /vmfs/volumes/58689744-b4b1ddd8-519b-001fc69c1ddf/.locker

But rebooting doesn't change the scratch location.

vi /etc/vmware/locker.conf
  /vmfs/volumes/ssd/.locker 0

I just spent 30 minutes chasing my tail: there are TWO volumes which start with /vmfs/volumes/5868..., but only the USB shows up in df (the SSD shows up as /vmfs/volumes/ssd

I see the following troubling messages in /var/log/vmkernel.log:

2017-02-25T17:34:15.505Z cpu0:65560)NMP: nmp_ThrottleLogForDevice:3617: Cmd 0x2a (0x439500a7f200, 65693) to dev "t10.ATA_____Crucial_CT1050MX300SSD4_________________________163713E82C00" on path "vmhba0:C0:T0:L0" Failed: H:0x2 D:0x0 P:0x0 Invalid sense $
2017-02-25T17:34:15.505Z cpu0:65560)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:237: NMP device "t10.ATA_____Crucial_CT1050MX300SSD4_________________________163713E82C00" state in doubt; requested fast path state update...
2017-02-25T17:34:15.505Z cpu0:65560)ScsiDeviceIO: 2927: Cmd(0x439500a7f200) 0x2a, CmdSN 0xaa9 from world 65693 to dev "t10.ATA_____Crucial_CT1050MX300SSD4_________________________163713E82C00" failed H:0x2 D:0x0 P:0x0 Invalid sense data: 0x75 0x70 0x64.
2017-02-25T17:34:15.762Z cpu3:65563)NMP: nmp_ThrottleLogForDevice:3546: last error status from device t10.ATA_____Crucial_CT1050MX300SSD4_________________________163713E82C00 repeated 10 times

Let's try updating:

esxcli software profile update -d https://hostupdate.vmware.com/software/VUM/PRODUCTION/main/vmw-depot-index.xml -p ESXi-6.5.0-20170104001-standard

Update did not fix the problem:

2017-02-25T17:55:58.931Z cpu2:65562)NMP: nmp_ThrottleLogForDevice:3617: Cmd 0x2a (0x439500b9e200, 66300) to dev "t10.ATA_____Crucial_CT1050MX300SSD4_________________________163713E82C00" on path "vmhba0:C0:T0:L0" Failed: H:0x2 D:0x0 P:0x0 Invalid sense $
2017-02-25T17:55:58.931Z cpu2:65562)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:237: NMP device "t10.ATA_____Crucial_CT1050MX300SSD4_________________________163713E82C00" state in doubt; requested fast path state update...
2017-02-25T17:55:58.931Z cpu2:65562)ScsiDeviceIO: 2927: Cmd(0x439500b9e200) 0x2a, CmdSN 0x75d from world 66300 to dev "t10.ATA_____Crucial_CT1050MX300SSD4_________________________163713E82C00" failed H:0x2 D:0x0 P:0x0 Invalid sense data: 0x75 0x70 0x64.
2017-02-25T17:55:59.445Z cpu6:67937)vmw_ahci[00000017]: scsiUnmapCommand:Unmap transfer 0x18 byte
2017-02-25T17:55:59.452Z cpu3:65563)NMP: nmp_ThrottleLogForDevice:3546: last error status from device t10.ATA_____Crucial_CT1050MX300SSD4_________________________163713E82C00 repeated 10 times

Saw the following while running bonnie++:

2017-02-25T18:19:29.773Z cpu6:65581)vmw_ahci[00000017]: scsiTaskMgmtCommand:VMK Task: VIRT_RESET initiator=0x43029e371440
2017-02-25T18:19:29.773Z cpu6:65581)vmw_ahci[00000017]: ahciAbortIO:(curr) HWQD: 0 BusyL: 0
2017-02-25T18:19:29.775Z cpu6:65581)vmw_ahci[00000017]: scsiTaskMgmtCommand:VMK Task: VIRT_RESET initiator=0x43029e371440
2017-02-25T18:19:29.775Z cpu6:65581)vmw_ahci[00000017]: ahciAbortIO:(curr) HWQD: 0 BusyL: 0
2017-02-25T18:19:29.777Z cpu6:65581)vmw_ahci[00000017]: scsiTaskMgmtCommand:VMK Task: VIRT_RESET initiator=0x43029e371440
2017-02-25T18:19:29.777Z cpu6:65581)vmw_ahci[00000017]: ahciAbortIO:(curr) HWQD: 0 BusyL: 0
2017-02-25T18:19:29.779Z cpu6:65581)vmw_ahci[00000017]: scsiTaskMgmtCommand:VMK Task: VIRT_RESET initiator=0x43029e371440
2017-02-25T18:19:29.779Z cpu6:65581)vmw_ahci[00000017]: ahciAbortIO:(curr) HWQD: 0 BusyL: 0
2017-02-25T18:19:29.783Z cpu0:68447)WARNING: FS3J: 3034: Aborting txn callerID: 0xc1d00006 to slot 211:  File system timeout (Ok to retry)
2017-02-25T18:19:29.783Z cpu3:68444)HBX: 2956: 'ssd': HB at offset 3735552 - Waiting for timed out HB:

In the Web Host -> Monitor -> Events, I see log messages such as "Lost access to volume 58689...." and "Successfully restored access to volume 58689..."

Let's try resetting BIOS (ugh).

Bumped the BIOS from 0037 to 0042, and reset to defaults, and booted. Ran bonnie++, saw "Lost access to volume..."

esxcli storage core adapter list
esxcli storage core device list

Smart Status:

esxcli storage core device smart get -d t10.ATA_____Crucial_CT1050MX300SSD4_________________________163713E82C00 | grep -v "N/A"
  Parameter                     Value  Threshold  Worst
  ----------------------------  -----  ---------  -----
  Read Error Count              100    0          100
  Power-on Hours                100    0          100
  Power Cycle Count             100    0          100
  Reallocated Sector Count      100    10         100
  Raw Read Error Rate           100    0          100
  Drive Temperature             66     0          50
  Initial Bad Block Count       100    0          100

Let's update the firmware on the Crucial SSD:

hdiutil convert -format UDRW -o /tmp/crucial.dmg ~/Downloads/mx300_revM0CR040_bootable_media_update.iso
sudo dd if=/tmp/crucial.dmg of=/dev/rdisk1 bs=1m

Updating: Download https://hostupdate.vmware.com/software/VUM/PRODUCTION/main/esx/vmw/vmw-ESXi-6.5.0-metadata.zip and check /profiles/, then run the following:

esxcli system version getesxcli system version get
esxcli software profile update -d https://hostupdate.vmware.com/software/VUM/PRODUCTION/main/vmw-depot-index.xml -p ESXi-6.5.0-20170404001-standard

When installing vcenter:

  • IPv4
    • 10.0.9.105 / 24
    • 10.0.9.1
  • IPv6
    • 2601:646:102:95::105/64
    • fe80::82ea:96ff:fee7:5524

Updates

Sun Apr 19 07:52:34 PDT 2020

Update BIOS & BMC on esxi-1 (X10SDV-8C-TLN4f+)

old new newer
BIOS 2.0a (10/12/2018) 2.1 (11/22/2019)
BMC Firmware 03.68 (03/20/2018) 03.86 (11/15/2019) 03.88 (02/21/2020)

Tue Apr 21 06:18:16 PDT 2020

Update BIOS & BMC on esxi-2 (X11SDV-8C+-TLN2F+) (search for it as "X11SDV-8C+-TLN2F")

old new newer
BIOS 1.0b (10/08/2018) 1.3 (03/05/2020) 1.4 (12/30/2020)
BMC Firmware 01.14 (01/18/2018) 01.31.02 (11/15/2019) 01.31.03 (04/15/2020)

Wed May 13 07:06:24 PDT 2020

To quiet the CPU Fan:

  • Log into IPMI
  • Configuration → Fan Mode
  • Select Set Fan to PUE2 (Power Utilization Effectiveness) Speed; click Save

You can do the following, too, but it doesn't seem to help much:

Configure BIOS & BMC on esxi-2 (X11SDV-8C+-TLN2F+) to make it less noisy:

Advanced → CPU P State Control

Original New
Uncore Freq Scaling (UFS) Enable Disable
SpeedStep (Pstates) Enable Disable
Config TDP Nominal
EIST PSD Function HW_ALL
Energy Efficient Turbo Enable
Turbo Mode Enable

It seems to have made it a little better, but I think the real solution is a quiet fan.

Wed May 13 10:02:33 PDT 2020

Measuring sound.

Sound measurement:

  • the "Sound Meter"
  • placed (from my viewpoint) on the lower left side of the top of esxi-2's case
  • reset
  • let run for 30 seconds
  • take average
esxi-2 Fan Mode Fan RPM Pillow (dB) Case (dB)
Powered-off N/A N/A 0 32 49
Maintenance Mode PUE2 old 4200 32 54
Maintenance Mode PUE2 new 1500 34 51
Partially loaded PUE2 old 5600 34 60
Partially loaded PUE2 new 2700 34 51
Fully loaded PUE2 old 6000 34 61
Fully loaded PUE2 new 3600 34 54
Fully loaded Optimal old 6700 35 62
Fully loaded Full old 8900 37 66

My goal is 54 dB at the case, 32 dB at my pillow, which I almost achieved except it's 34 dB at my pillow (to the sound meter), but to my ears it's perfectly quiet.

The CPU is 67° C fully loaded with the new fan, which is fine.

To install a quieter fan: https://www.servethehome.com/near-silent-powerhouse-making-a-quieter-microlab-platform/

  • old fan: Nidec UltraFlo™ H60T12BHA7-57 (stock fan)
  • new fan: Noctua NF-A6x25

Sat Dec 26 07:41:23 PST 2020

Deleting Stale Trusted Root Certificates.

Warning: we encourage you to follow the documentation from VMware: Removing Expired CA Certificates from the TRUSTED_ROOTS store in the VMware Endpoint Certificate Store (VECS) (2146011).

ssh root@vcenter-70.nono.io
shell
/usr/lib/vmware-vmafd/bin/vecs-cli entry list --store TRUSTED_ROOTS | less

Find the root cert we need to keep; we determined that 75cca4058c8abf184c9d61a78559fd02504dde7b was the root certificate we needed to keep because its OU (Organization Unit) was VMware Engineering, as seen by clicking the View Details link of the certificate, and the expiration was approximately ten years from when we generated the certificate.

/usr/lib/vmware-vmafd/bin/vecs-cli entry list --store TRUSTED_ROOTS |
  grep -v 75cca4058c8abf184c9d61a78559fd02504dde7b |
  grep "^Alias :" |
  cut -f3

Find the Canonical name of the CA certificate, which is easy because that's the name of the certificate when browsing to Menu → Administration → Certificates → Certificate Management → Trusted Root Certificates. Look for the certificate that is generated by VMware Engineering and that expires approximately ten years from when you generated the certificates (or when you installed the vCenter). In our case, the CN(id) is 309BE953ADE21D9736E283C2C597A45A1784745A

Note: I never finished this process; I got bored.

Why doesn't vCenter 70 Lifecycle Manager not work

From https://vcenter-70.nono.io/ui/app/admin/plugins Stack Trace:

Error downloading plug-in. Make sure that the URL is reachable and the registered thumbprint is correct.
java.net.ConnectException: Connection refused (Connection refused)
java.net.PlainSocketImpl.socketConnect(Native Method)
java.net.AbstractPlainSocketImpl.doConnect(AbstractPlainSocketImpl.java:350)
java.net.AbstractPlainSocketImpl.connectToAddress(AbstractPlainSocketImpl.java:206)
java.net.AbstractPlainSocketImpl.connect(AbstractPlainSocketImpl.java:188)
java.net.SocksSocketImpl.connect(SocksSocketImpl.java:392)
java.net.Socket.connect(Socket.java:607)
sun.security.ssl.SSLSocketImpl.connect(SSLSocketImpl.java:681)
sun.net.NetworkClient.doConnect(NetworkClient.java:175)
sun.net.www.http.HttpClient.openServer(HttpClient.java:463)
sun.net.www.http.HttpClient.openServer(HttpClient.java:558)
sun.net.www.protocol.https.HttpsClient.<init>(HttpsClient.java:264)
sun.net.www.protocol.https.HttpsClient.New(HttpsClient.java:367)
sun.net.www.protocol.https.AbstractDelegateHttpsURLConnection.getNewHttpClient(AbstractDelegateHttpsURLConnection.java:191)
sun.net.www.protocol.http.HttpURLConnection.plainConnect0(HttpURLConnection.java:1162)
sun.net.www.protocol.http.HttpURLConnection.plainConnect(HttpURLConnection.java:1056)
sun.net.www.protocol.https.AbstractDelegateHttpsURLConnection.connect(AbstractDelegateHttpsURLConnection.java:177)
sun.net.www.protocol.http.HttpURLConnection.getInputStream0(HttpURLConnection.java:1570)
sun.net.www.protocol.http.HttpURLConnection.getInputStream(HttpURLConnection.java:1498)
java.net.HttpURLConnection.getResponseCode(HttpURLConnection.java:480)
sun.net.www.protocol.https.HttpsURLConnectionImpl.getResponseCode(HttpsURLConnectionImpl.java:352)
com.vmware.vise.util.http.ConnectionManager.connect(ConnectionManager.java:284)
com.vmware.vise.util.http.SimpleHttpClient.connect(SimpleHttpClient.java:354)
com.vmware.vise.util.http.SimpleHttpClient.connect(SimpleHttpClient.java:324)
com.vmware.vise.util.http.SimpleHttpClient.executeMethodResponseAsStream(SimpleHttpClient.java:222)
com.vmware.vise.util.http.SimpleHttpClient.executeMethodResponseAsStream(SimpleHttpClient.java:244)
com.vmware.vise.plugin.discovery.directory.impl.DirectoryExtensionManagerImpl.writePackageToFile(DirectoryExtensionManagerImpl.java:598)
com.vmware.vise.plugin.discovery.directory.impl.DirectoryExtensionManagerImpl.downloadTempFile(DirectoryExtensionManagerImpl.java:525)
com.vmware.vise.plugin.discovery.directory.impl.DirectoryExtensionManagerImpl.downloadPackage(DirectoryExtensionManagerImpl.java:484)
com.vmware.vise.plugin.discovery.directory.impl.DirectoryExtensionManagerImpl.downloadAndDeployPackage(DirectoryExtensionManagerImpl.java:423)
com.vmware.vise.plugin.discovery.directory.impl.DirectoryExtensionManagerImpl$1.call(DirectoryExtensionManagerImpl.java:355)
com.vmware.vise.plugin.discovery.directory.impl.DirectoryExtensionManagerImpl$1.call(DirectoryExtensionManagerImpl.java:350)
java.util.concurrent.FutureTask.run(FutureTask.java:266)
com.vmware.vise.util.concurrent.QueuingCachedThreadPool$QueueProcessor.run(QueuingCachedThreadPool.java:1271)
java.util.concurrent.Executors$RunnableAdapter.call(Executors.java:511)
java.util.concurrent.FutureTask.run(FutureTask.java:266)
java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1149)
java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:624)
com.vmware.vise.util.concurrent.WorkerThreadFactory$1.run(WorkerThreadFactory.java:64)
java.lang.Thread.run(Thread.java:748)

Following these instructions, ssh onto vcenter:

/usr/lib/vmware-lookupsvc/tools/lstool.py list --url https://localhost/lookupservice/sdk --type com.vmware..vr.vrms
...
Caused by: javax.net.ssl.SSLException: Certificate for <localhost> doesn't match any of the subject alternative names: [vcenter-70.nono.io, www.vcenter-70.nono.io]

Let's try again, but not using localhost:

/usr/lib/vmware-lookupsvc/tools/lstool.py list --url https://vcenter-70.nono.io/lookupservice/sdk --type com.vmware..vr.vrms
  (nothing but Java stuff: "Picked up JAVA_TOOL_OPTIONS: -Xms32M -Xmx128M..."
/usr/lib/vmware-lookupsvc/tools/lstool.py list --url https://vcenter-70.nono.io/lookupservice/sdk --type vrUi

Let's try again, but using stackoverflow:

/usr/lib/vmware-lookupsvc/tools/lstool.py list --ep-type com.vmware.cis.vsphereclient.plugin --url http://localhost:7090/lookupservice/sdk

There are several variants of the h4 plugin; deleting the old ones (0.3.5.0, 0.4.0.0)

/usr/lib/vmware-lookupsvc/tools/lstool.py unregister \
    --url http://localhost:7090/lookupservice/sdk \
    --user 'administrator@vsphere.local' \
    --password 'yourpassword' \
    --no-check-cert \
    --id a70e03ca-2f78-44d8-b120-85997274aeca

It looks like there's still the broken lifecycle manager, and I believe this is the plugin info:

	Name: cis.updatemgr.ServiceName
	Description: cis.updatemgr.ServiceDescription
	Service Product: com.vmware.vum
	Service Type: client
	Service ID: 29f99f31-afd8-419b-8803-f899362209f6
	Site ID: default-site
	Node ID: 3bd2599c-38e9-42e1-adbf-32341a6b50cd
	Owner ID: vpxd-extension-23be793a-68b2-4f05-993c-c38f9cb1f391@vsphere.local
	Version: 7.0.1.17451065
	Endpoints:
		Type: com.vmware.cis.vsphereclient.plugin
		Protocol: http
		URL: https://vcenter-70.nono.io:9087/vci/downloads/vum-htmlclient.zip
		SSL trust: 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
		Endpoint Attributes:
			company: VMware, Inc
			adminEmail: noreply@vmware.com
	Attributes:
		com.vmware.cis.cm.ControlScript: service-control-default-vmon
		com.vmware.cis.cm.HostId: 23be793a-68b2-4f05-993c-c38f9cb1f391

There's nothing listening on 9087, but there is a vum-htmlclient.zip:

find / -name vum-htmlclient.zip -ls
  2753944   6664 -rw-r--r--   1  updatemgr updatemgr  6822780 Jan 20 18:09 /usr/lib/vmware-updatemgr/bin/docroot/vci/downloads/vum-htmlclient.zip

Let's see if we can download this over any endpoint:

for PORT in $(ss -lntp | grep "*:" | grep -v 127.0.0.1 | awk '{print $4}' | sed "s=*:=="); do
  curl --user 'a@vsphere.local:xxx' -k -I http://vcenter-70.nono.io:$PORT/vci/downloads/vum-htmlclient.zip
  curl --user 'a@vsphere.local:xxx' -k -I https://vcenter-70.nono.io:$PORT/vci/downloads/vum-htmlclient.zip
  break
done

Mostly 404s, a bunch of OpenSSL errors.

I think I need to give up on Lifecycle Manager & use the old, manual way.

Notice the control script has vmon—maybe there's a log?

less /var/log/vmware/vmon/vmon.log

Let's look for updatemgr:

Adding service updatemgr.
<updatemgr-prestart> Constructed command: /usr/bin/python /usr/lib/vmware-updatemgr/bin/updatemgr-vmon-prestart.py
<updatemgr> Service pre-start command completed successfully.
<updatemgr> Constructed command: /usr/lib/vmware-updatemgr/bin/vmware-updatemgr /usr/lib/vmware-updatemgr/bin/vci-integrity.xml
<updatemgr> Running the API Health command as user updatemgr
<updatemgr-healthcmd> Constructed command: /usr/bin/python /usr/lib/vmware-updatemgr/bin/updatemgr-vmon-apihealth.py
<updatemgr> Service STARTED successfully.
<event-pub> Constructed command: /usr/bin/python /usr/lib/vmware-vmon/vmonEventPublisher.py --eventdata updatemgr,HEALTHY,UNHEALTHY,0 --eventdata vlcm,HEALTHY,UNHEALTHY,0
<updatemgr> Service is dumping core. Coredump count 5. CurrReq: 0
<updatemgr> Initiating core dump recovery action.
<event-pub> Constructed command: /usr/bin/python /usr/lib/vmware-vmon/vmonEventPublisher.py --eventdata wcp,HEALTHY,UNHEALTHY,0 --eventdata updatemgr,UNHEALTHY,HEALTHY,1
<updatemgr> Service exited. Exit code 1
<updatemgr> Service exited unexpectedly. Crash count 5. Taking configured recovery action.
<updatemgr> Skip service health check. State STOPPED, Curr request 0
<updatemgr> Skip service health check. State STOPPED, Curr request 0
<updatemgr> Skip service health check. State STOPPED, Curr request 0
<updatemgr> Skip service health check. State STOPPED, Curr request 0

If I look at vci-integrity.xml, I see juicy things like the port (9087) and the log file (vmware-vum-server)

less /storage/log/vmware/vmware-updatemgr/vum-server/vmware-vum-server.log

Nothing in the log file, but I found the core dumps!

file /storage/core/core.worker.9353
core.worker.9353: ELF 64-bit LSB core file, x86-64, version 1 (SYSV), SVR4-style, from '/usr/lib/vmware-updatemgr/bin/updatemgr /usr/lib/vmware-updatemgr/bin/vci-integ', real uid: 1017, effective uid: 1017, real gid: 990, effective gid: 990, execfn: '/usr/lib/vmware-updatemgr/bin/updatemgr', platform: 'x86_64'

Let's crack open gdb:

gdb /usr/lib/vmware-updatemgr/bin/updatemgr /storage/core/core.worker.9353
(gdb) bt
#0  0x00007fd1ced2e7ba in raise () from /usr/lib/libc.so.6
#1  0x00007fd1ced2f851 in abort () from /usr/lib/libc.so.6
#2  0x00007fd1d3220078 in Vmacore::System::SignalTerminateHandler (info=info@entry=0x0, ctx=ctx@entry=0x0) at bora/vim/lib/vmacore/posix/defSigHandlers.cpp:62
#3  0x00007fd1d3220088 in Vmacore::System::TerminateHandler () at bora/vim/lib/vmacore/posix/defSigHandlers.cpp:78
#4  0x00007fd1d1a402d6 in ?? () from /usr/lib/vmware-updatemgr/bin/../lib/libstdc++.so.6
#5  0x00007fd1d1a40321 in std::terminate() () from /usr/lib/vmware-updatemgr/bin/../lib/libstdc++.so.6
#6  0x00007fd1d1a40538 in __cxa_throw () from /usr/lib/vmware-updatemgr/bin/../lib/libstdc++.so.6
#7  0x00007fd1d321caa9 in Vmacore::System::ThrowFileIOException (filePath=..., error=<optimized out>) at bora/vim/lib/vmacore/posix/fileIO.cpp:61
#8  0x00007fd1d321cbda in Vmacore::System::FileReaderPosix::Open (this=this@entry=0x7fd1c8785f40, filePath=...) at bora/vim/lib/vmacore/posix/fileIO.cpp:230
#9  0x00007fd1d3109de9 in Vmacore::System::SystemFactory::CreateFileReader (this=<optimized out>, filePath=..., out=...) at bora/vim/lib/vmacore/system/systemFactory.cpp:469
#10 0x00007fd1ce3f0e2d in Sysimage::xmlParser::Parse(std::string const&) () from /usr/lib/vmware-updatemgr/bin/../lib/libvci-vcIntegrity.so
#11 0x00007fd1ce2c7fa3 in Integrity::HostUpdate20::PatchDepotManager::GetVendorMap(std::string const&, Integrity::DepotManager::DepotManagerType, std::shared_ptr<Integrity::HostUpdate20::InternalMap<std::map<std::string, Integrity::HostUpdate20::Vendor, std::less<std::string>, std::allocator<std::pair<std::string const, Integrity::HostUpdate20::Vendor> > > > >&) () from /usr/lib/vmware-updatemgr/bin/../lib/libvci-vcIntegrity.so
#12 0x00007fd1ce2c83d4 in Integrity::HostUpdate20::PatchDepotManager::GetMicroDepots(std::set<std::string, std::less<std::string>, std::allocator<std::string> >&) ()
   from /usr/lib/vmware-updatemgr/bin/../lib/libvci-vcIntegrity.so
#13 0x00007fd1c780cdf1 in Integrity::VapiPlugin::InitiateDefaultTasks() () from /usr/lib/vmware-updatemgr/bin/../lib/libvci-vapi.so
#14 0x00007fd1d31a5e76 in Vmacore::System::ThreadPoolFair::InvokeItem(std::function<void ()>&) const (this=this@entry=0x166c610, item=...)
    at bora/vim/lib/vmacore/asio/ThreadPoolFair.cpp:632
#15 0x00007fd1d31ab4d4 in Vmacore::System::ThreadPoolFair::RunWorkerThread (this=0x166c610) at bora/vim/lib/vmacore/asio/ThreadPoolFair.cpp:1302
#16 0x00007fd1d3224dac in std::function<void ()>::operator()() const (this=<optimized out>)
    at /build/mts/release/bora-17451052/BOD/vcenter-vpxlibs/linx64/release/f8c200f/build/bora/build/package/COMPONENTS/cayman_esx_toolchain/ob-15599702/linux64/usr/x86_64-vmk-linux-gnu/include/c++/6.4.0/functional:2127
#17 Vmacore::System::ThreadPosix::ThreadBegin (data=<optimized out>) at bora/vim/lib/vmacore/posix/thread.cpp:122
#18 0x00007fd1d1781f87 in start_thread () from /usr/lib/libpthread.so.0
#19 0x00007fd1cedec5bf in clone () from /usr/lib/libc.so.6

Okay, let's find out what the filePath on #7 is.

(gdb) up 7
#7  0x00007fd1d321caa9 in Vmacore::System::ThrowFileIOException (filePath=..., error=<optimized out>) at bora/vim/lib/vmacore/posix/fileIO.cpp:61
61	bora/vim/lib/vmacore/posix/fileIO.cpp: No such file or directory.
(gdb) p filePath
$1 = (const std::string &) @0x7fd1c8785f60: {static npos = 18446744073709551615,
  _M_dataplus = {<std::allocator<char>> = {<__gnu_cxx::new_allocator<char>> = {<No data fields>}, <No data fields>},
    _M_p = 0x7fd1c8786008 "/storage/updatemgr/patch-store/hostupdate/__hostupdate20-consolidated-index__.xml"}}

Well, that's an interesting filepath: /storage/updatemgr/patch-store/hostupdate/__hostupdate20-consolidated-index__.xml

Let's try resetting the updatemgr db:

service-control --stop vmware-updatemgr
/usr/lib/vmware-updatemgr/bin/updatemgr-utility.py reset-db
rm -rf /storage/updatemgr/patch-store/*
service-control --start vmware-updatemgr

Adding a 250 GiB Datastore

  • Browse to NAS and login: https://nas.nono.io
  • Storage → Pools → right click on ⠇ on pool "tank"
  • Select "Add Zvol"
    • Zvol name: NAS-1
    • Comments: For vSphere HA heartbeat
    • Size for this zvol: 250 GiB
    • Check "Sparse" (thin provisioning)
    • Click Submit
  • Services → iSCSI / Actions / ✎
    • Extents → ADD
      • Name: NAS-1
      • Device: tank/NAS-1 (250G)
      • Click SUBMIT
    • Associated Targets → ADD
      • Target: vsphere
      • Extent: NAS-1
      • Click SUBMIT
  • Browse to vCenter and login: <vcenter-70.nono.io>
    • esxi-1.nono.io → Configure → Storage Adapters → Rescan Storage
    • esxi-1.nono.io → Datastores → Actions → Storage → New Datastore
      • Type: VMFS
      • Name: NAS-1
      • VMFS 6
      • NEXT, NEXT, FINISH

Updating the BIOS, again

old new
BIOS 2.1 (11/22/2019) 2.3 (06/04/20201

Configure BIOS

  • Save & Exit → Restore Optimized Defaults
  • Save Changes & Reset

Press F11 on boot to choose bootable device. If you're using the soft keyboard, make sure to move it down because the screen jumps bigger.

Choose "Samsung Flash Drive FIT 1100" not "UEFI: Samsung ..."

Later, during the install process, choose a UEFI install. And then, to boot to the installed drive, choose the UEFI variant, "UEFI: ...".

Rebooting from the CLI

Make sure you're in maintenance mode:

esxcli system shutdown poweroff --reason "Add new Nvidia T4 card"
esxcli system shutdown reboot   --reason "Attempt to recognize new Nvidia T4 card"

Nvidia

These are notes from my Nvidia T4 installation:

  • Register for the free trial https://www.nvidia.com/en-us/data-center/resources/vgpu-evaluation/

  • Log into https://nvid.nvidia.com, bcunnie@vmware.com

    • click on "Nvidia Licensing Portal"
    • click on Get Started; this part was straightforward. I don't know if it was strictly necessary.
  • Download the software:

    • click on Software Downloads. Look for platform "VMware vSphere" and platform version "8.0". Click "Download". It'll download something like /Users/cunnie/Downloads/NVIDIA-GRID-vSphere-8.0-535.104.06-535.104.05-537.13.zip.
    • Once you unzip that file, you'll see the drivers for ESXi (Host_Drivers/) and for the VMs (Guest_Drivers/)
    • Unzip NVD-VGPU-800_535.104.06-1OEM.800.1.0.20613240_22326085.zip in the Host_Drivers/ subdirectory.
  • Copy the .vib file onto the ESXi host:

scp \
  ~/Downloads/NVIDIA-GRID-vSphere-8.0-535.104.06-535.104.05-537.13/Host_Drivers/NVD-VGPU-800_535.104.06-1OEM.800.1.0.20613240_22326085/vib20/NVD-VMware_ESXi_8.0.0_Driver/NVD_bootbank_NVD-VMware_ESXi_8.0.0_Driver_535.104.06-1OEM.800.1.0.20613240.vib \
  esxi-2:/vmfs/volumes/NAS-0/ISO/
 # put the host in Maintenance Mode from the console not `esxcli`
 # because `esxcli` won't migrate the VMs
cd /vmfs/volumes/NAS-0/ISO # wherever you copied it to, but not in homedir--too small
esxcli software vib install -v $PWD/NVD_bootbank_NVD-VMware_ESXi_8.0.0_Driver_535.104.06-1OEM.800.1.0.20613240.vib
esxcli system shutdown reboot --reason "Install Nvidia vGPU drivers"
 # after logging in after reboot
esxcli system maintenanceMode set --enable false
  • Sometimes the T4 isn't recognized/available when the ESXi host is booted; try rebooting the host again.
  • On the VM (client), a good way to install the drivers is to follow the VMware KB article is to install the Debian package along with the dkms package, i.e.:
sudo apt-get install dkms
sudo dpkg -i $HOME/Downloads/NVIDIA-GRID-vSphere-8.0-535.54.06-535.54.03-536.25/Guest_Drivers/nvidia-linux-grid-535_535.54.03_amd64.deb
nvidia-smi
  • When configuring a VM with vGPU, do the following on GUI: VM → VM Hardware Edit → Add New Device → Add PCI Device. You should be prompted with several "NVIDIA GRID VGPU" devices; select one, e.g. grid_t4-1q. Use the drivers that end in "q". The number before the "q" is the amount of RAM, e.g. grid_t4-16q will use all of the T4's 16 MB.

Note: In general, we're interested in the "grid" flavor of drivers.

For setting up a "passthrough", watch How to pass through a GPU in VMware ESXi 8.