Notifications
You must be signed in to change notification settings - Fork 0
/
winix-02.py
549 lines (432 loc) · 22.2 KB
/
winix-02.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
#! /usr/bin/env python3
#
# winix-02.py
# 202012031810
#
#
PROGRAM_NAME = "winix-02"
VERSION_MAJOR = "1"
VERSION_MINOR = "13"
WORKING_DIRECTORY = "/home/user/winix/"
# winix URL's
GET_STATUS_URL = "https://us.api.winix-iot.com/common/event/sttus/devices/"
COMMAND_URL = "https://us.api.winix-iot.com/common/control/devices/"
#
#
#
import sys
import cProfile
# check version of python
if not (sys.version_info.major == 3 and sys.version_info.minor >= 7):
print("This script requires Python 3.7 or higher!")
print("You are using Python {}.{}.".format(sys.version_info.major, sys.version_info.minor))
sys.exit(1)
#print("{} {} is using Python {}.{}.".format(PROGRAM_NAME, PROGRAM_VERSION, sys.version_info.major, sys.version_info.minor))
import json
from urllib import request
import traceback
from pathlib import Path
import yaml
import queue
from dateutil.parser import parse
import paho.mqtt.client as mqtt
import time
from datetime import datetime
from timeloop import Timeloop
from datetime import timedelta
from dateutil import tz
import logging
import logging.handlers
# Logging setup
# select logging level
logging_level_file = logging.getLevelName('DEBUG')
#level_file = logging.getLevelName('DEBUG')
logging_level_rsyslog = logging.getLevelName('INFO')
# set local logging
LOG_FILENAME = PROGRAM_NAME + '.log'
root_logger = logging.getLogger()
#set loggers
# file logger
handler_file = logging.handlers.RotatingFileHandler(WORKING_DIRECTORY + LOG_FILENAME, backupCount=5)
handler_file.setFormatter(logging.Formatter(fmt='%(asctime)s %(levelname)-8s ' + PROGRAM_NAME + ' ' + '%(message)s', datefmt='%Y-%m-%d %H:%M:%S'))
handler_file.setLevel(logging_level_file)
root_logger.addHandler(handler_file)
# Roll over on application start
handler_file.doRollover()
# configure highest level combo logger, this is what we log to and it automagically goes to the log receivers that we have configured
# logging.getLogger("timeloop").setLevel(logging.CRITICAL)
my_logger = logging.getLogger(PROGRAM_NAME)
# read yaml config file which lists the air purifer units
try :
raw_yaml = Path(WORKING_DIRECTORY + PROGRAM_NAME + ".yaml").read_text()
except Exception as e:
my_logger.error("Error : configuration file : " + WORKING_DIRECTORY + PROGRAM_NAME + ".yaml" + " not found.")
sys.exit(1)
try :
PROGRAM_CONFIG = yaml.load(Path(WORKING_DIRECTORY + PROGRAM_NAME + ".yaml").read_text(), Loader=yaml.FullLoader)
except Exception as e :
my_logger.error("Error : YAML syntax problem in configuration file : " + WORKING_DIRECTORY + PROGRAM_NAME + ".yaml" + " .")
sys.exit(1)
# read debug from YAML config file
# simple key value pair in YAML file : debug_level: "level" and set debug level
DEBUG_LEVEL = PROGRAM_CONFIG.get("debug_level", "")
if ( DEBUG_LEVEL == "" ) :
DEBUG_LEVEL = "INFO"
logging_level_file = logging.getLevelName(DEBUG_LEVEL)
handler_file.setLevel(logging_level_file)
# read MQTT server info from YAML config file
# simple key value pair in YAML file : mqtt: "<mqtt server info>"
MQTT_SERVER = PROGRAM_CONFIG.get("mqtt", "")
if ( MQTT_SERVER == "" ) :
MQTT_SERVER = "192.168.2.242"
# read MQTT server info from YAML config file
# simple key value pair in YAML file : mqtt: "<mqtt server info>"
MQTT_TOPIC_BASE = PROGRAM_CONFIG.get("mqtt_topic", "")
if ( MQTT_TOPIC_BASE == "" ) :
MQTT_TOPIC_BASE = "winix"
# remove any forward slashes in value received from config file and just make it simple name with one following forward slash
MQTT_TOPIC_BASE = MQTT_TOPIC_BASE.strip( "/" ) + "/"
MQTT_CONTROL_TOPIC = "/control/"
MQTT_STATUS_TOPIC = ""
# read rsyslog info from YAML config file
# simple key value pair in YAML file : rsyslog: "<rsyslog server info>"
# simple string
RSYSLOG_SERVER = PROGRAM_CONFIG.get("rsyslog", "")
LOG_RSYSLOG = (RSYSLOG_SERVER, 514)
# rsyslog handler, if an IP address was specified in the YAML config file that configure to log to a RSYSLOG server
if (RSYSLOG_SERVER != "") :
handler_rsyslog = logging.handlers.SysLogHandler(address = LOG_RSYSLOG)
handler_rsyslog.setFormatter(logging.Formatter(fmt='%(asctime)s %(levelname)-8s ' + PROGRAM_NAME + ' ' + '%(message)s', datefmt='%Y-%m-%d %H:%M:%S'))
handler_rsyslog.setLevel(logging_level_rsyslog)
root_logger.addHandler(handler_rsyslog)
logging_level_file = logging.getLevelName('DEBUG')
root_logger.setLevel(logging_level_file)
# how often to check the winix cloud for updated from each unit, be careful to not be to quick at updates
# this is in minutes
CHECK_PERIOD_MINUTES = PROGRAM_CONFIG.get("check_interval", 5)
# delay in seconds between API calls, so as to not flood the cloud server
API_DELAY_SECONDS = 5
# winix units info from YAML config file
# dictionary of dictionaries
# units:
# example line : "SB01" : {"home" : "South Beach", "room" : "Living Room", "key" : "zzzzzzzzzzzzzzzzzzzzzzzzzzzzzz", , "mac_address" : "xx:xx:xx:xx:xx:xx"}
UNITS = PROGRAM_CONFIG.get("units", {})
# build another dictionary, so that we can lookup the unit's key by it's mac address
UNITS_BY_MAC = {}
for unit in UNITS :
UNITS_BY_MAC[UNITS[unit]['mac_address']] = UNITS[unit]
# global dictionary to keep track of current state of each unit
UNITS_BY_MAC_STATE = {}
# debug, check that the YAML reads and massaging are correct
my_logger.debug("MQTT_SERVER :" + str(MQTT_SERVER))
my_logger.debug("MQTT_TOPIC_BASE :" + str(MQTT_TOPIC_BASE))
my_logger.debug("LOG_RSYSLOG :" + str(LOG_RSYSLOG))
my_logger.debug("CHECK_PERIOD_MINUTES :" + str(CHECK_PERIOD_MINUTES))
my_logger.debug("UNITS :" + str(UNITS))
# api topics
POWER = {"COMMAND" : "A02", "ON" : "1", "OFF" : "0"}
OPERATION_MODE = {"COMMAND" : "A03", "AUTO" : "01", "MANUAL" : "02"}
PLASMAWAVE = {"COMMAND" : "A07", "ON" : "1", "OFF" : "0"}
FAN_SPEED = {"COMMAND" : "A04", "100" : "05", "75" : "03", "50" : "02", "25" : "01", "SLEEP" : "06"}
SLEEP = {"COMMAND" : "A04", "SLEEP" : "06"}
AIR_QUALITY = {"COMMAND" : "S07", "GOOD" : "01", "FAIR" : "02", "POOR" : "03"}
FILTER_HOURS = {"COMMAND" : "A21"}
AMBIENT_LIGHT = {"COMMAND" : "S14"}
AIR_QUALITY_VALUE = {"COMMAND" : "S08"}
# device characteristics
DEVICE_SPECIFICATION = {'manufacture' : ' WINIX', 'model' : 'C545', 'power' : '65 watts', 'room_size' : '360 sq. ft', 'weight' : '11.5 lbs'}
# setup timeloop, this allows to schedule the pull of units current status from winix cloud on regular basis
# https://github.com/sankalpjonn/timeloop
tl = Timeloop()
# create MQTT client globally
# connect to MQTT server
mqttc = mqtt.Client(PROGRAM_NAME) # Create instance of client with client ID
mqttc.connect(MQTT_SERVER, 1883) # Connect to (broker, port, keepalive-time)
# setup a simple queue where we can put a request for an update to a winix unit from the winix cloud
queue_unit_request_update = queue.SimpleQueue()
# functions to handle the command messages from MQTT sources
def message_to_or_from_unit(mosq, obj, msg) :
# we have to check all MQTT messages for either a command to the unit from an MQTT source
# or a status up MQTT message that was published by this routine (because the current state of a control,
# might have been change by a interaction with front panel of unit, or command from the mobile phone app)
global UNITS_BY_MAC_STATE
msg_text = msg.payload.decode("utf-8")
my_logger.debug("in messages_to_or_from_unit, message topic, qos, text: " + msg.topic + " " + str(msg.qos) + " " + msg_text)
# if the message is a status message, aka has subtopic of "$SYS" we can skip
if ( "$SYS" in msg.topic ) :
return
# get the MAC address of the unit that message is for or about
unit_mac = (msg.topic).strip( MQTT_TOPIC_BASE )[ 0: 17]
# key the unit key based on MAC address of unit
unit_key = UNITS_BY_MAC[unit_mac].get('key', '')
my_logger.debug("in messages_to_or_from_unit, UNIT MAC : |" + unit_mac + "|")
my_logger.debug("in messages_to_or_from_unit, UNIT KEY : |" + unit_key + "|")
msg_command = ""
# if MQTT topic contains the topic for sending command to unit, then decode the command to send and parameters
if ( MQTT_CONTROL_TOPIC in msg.topic ) :
unit_url = ""
if ( "power" in msg.topic ) :
if ( msg_text == "ON" ) :
msg_command = "1"
else :
msg_command = "0"
# create control URL
unit_url = COMMAND_URL + unit_key + "/A211/A02:" + msg_command
if ( "mode" in msg.topic ) :
if ( msg_text == "AUTO" ) :
msg_command = "01"
else :
msg_command = "03"
# create control URL
unit_url = COMMAND_URL + unit_key + "/A211/A03:" + msg_command
if ( "plasmawave" in msg.topic ) :
if ( msg_text == "ON" ) :
msg_command = "01"
else :
msg_command = "02"
# create control URL
unit_url = COMMAND_URL + unit_key + "/A211/A07:" + msg_command
if ( "fan_speed" in msg.topic ) :
msg_command = "01"
if ( msg_text == "100" ) :
msg_command = "05"
if ( msg_text == "75" ) :
msg_command = "03"
if ( msg_text == "50" ) :
msg_command = "02"
if ( msg_text == "25" ) :
msg_command = "01"
# create control URL
unit_url = COMMAND_URL + unit_key + "/A211/A04:" + msg_command
if ( "sleep" in msg.topic ) :
if ( msg_text == "ON" ) :
msg_command = "06"
else :
msg_command = "01"
# create control URL
unit_url = COMMAND_URL + unit_key + "/A211/A04:" + msg_command
# request undate from winix cloud for unit, no change command to send
if ( "update" in msg.topic ) :
my_logger.debug("Update from cloud requested for unit : " + unit_mac)
unit_url = ""
# if we received a valid MQTT command to send to winix cloud, do so
# the 'update' topic does not request any change, so for that MQTT topic we just skip sending
# and queue a status update
if ( len(unit_url) > 0 ) :
# send command to winix cloud for the unit
try :
my_logger.debug("Requested URL : " + unit_url)
unit_raw_json = json.loads(request.urlopen(unit_url).read().decode())
my_logger.debug("Returned data : " + str(unit_raw_json))
except Exception as e:
my_logger.error("Error : Unable to send Winix command URL : " + traceback.format_exc())
sys.exit(1)
# request the main loop do an update of the current status of this unit from winix cloud
# rather than waiting for next periodic update
my_logger.debug("command completed, queuing an update request for unit : " + unit_mac)
queue_unit_request_update.put(unit_mac)
# if not a control MQTT message then it is a status message that we requested from the winix cloud
# check to see if any of the control states have changed from what we think they are and update
# our local copy of current state of the unit
#
# NOTE: this is where the problem is, if a control state has changed, due to someone pressing buttons on front of unit
# or sending a command to the unit from the winix mobile app, we need to update the state in HA, but if we sent
# MQTT message with state control it comes back here a control message!!!!!
else :
msg_dict = json.loads(msg_text)
if ( unit_mac not in UNITS_BY_MAC_STATE.keys() ) :
UNITS_BY_MAC_STATE[unit_mac] = {"power_text": "UNKNOWN", "unit_mode_text": "UNKNOWN", "unit_plasmawave_text": "UNKNOWN", "unit_sleeping_text": "UNKNOWN", "unit_fan_speed_text": "UNKNOWN"}
if ( UNITS_BY_MAC_STATE[unit_mac]["power_text"] != msg_dict.get("power_text", "UNKNOWN") ) :
my_logger.debug("power_text changed : " + unit_mac)
UNITS_BY_MAC_STATE[unit_mac]["power_text"] = msg_dict.get("power_text", "UNKNOWN")
if ( UNITS_BY_MAC_STATE[unit_mac]["unit_mode_text"] != msg_dict.get("unit_mode_text", "UNKNOWN") ) :
my_logger.debug("unit_mode_text changed : " + unit_mac)
UNITS_BY_MAC_STATE[unit_mac]["unit_mode_text"] = msg_dict.get("unit_mode_text", "UNKNOWN")
if ( UNITS_BY_MAC_STATE[unit_mac]["unit_plasmawave_text"] != msg_dict.get("unit_plasmawave_text", "UNKNOWN") ) :
my_logger.debug("unit_plasmawave_text changed : " + unit_mac)
UNITS_BY_MAC_STATE[unit_mac]["unit_plasmawave_text"] = msg_dict.get("unit_plasmawave_text", "UNKNOWN")
if ( UNITS_BY_MAC_STATE[unit_mac]["unit_sleeping_text"] != msg_dict.get("unit_sleeping_text", "UNKNOWN") ) :
my_logger.debug("unit_sleeping_text changed : " + unit_mac)
UNITS_BY_MAC_STATE[unit_mac]["unit_sleeping_text"] = msg_dict.get("unit_sleeping_text", "UNKNOWN")
if ( UNITS_BY_MAC_STATE[unit_mac]["unit_fan_speed_text"] != msg_dict.get("unit_fan_speed_text", "UNKNOWN") ) :
my_logger.debug("unit_fan_speed_text changed : " + unit_mac)
UNITS_BY_MAC_STATE[unit_mac]["unit_fan_speed_text"] = msg_dict.get("unit_fan_speed_text", "UNKNOWN")
return
# function to request a status update for unit from winix cloud
def get_unit_update(unit_mac) :
try:
unit_key = UNITS_BY_MAC[unit_mac].get('key', '')
unit_url = GET_STATUS_URL + unit_key
my_logger.debug("Requested URL : " + unit_url)
unit_raw_json = json.loads(request.urlopen(unit_url).read().decode())
my_logger.debug("Returned data : " + str(unit_raw_json))
except Exception as e:
my_logger.error("Error : Unable to retrieve Winix status URL : " + traceback.format_exc())
return
# sys.exit(1)
# time of getting the status of unit from web api, not that this is the retrieval time of data from the web server
# the unit may not have updated the web server for a while
unit_status_retrieval_ts = int(time.time())
unit_body_json = unit_raw_json.get("body")
unit_data_json = unit_body_json.get("data")
unit_attributes_json = unit_data_json[0].get("attributes")
unit_mac_address = unit_mac
unit_model = unit_data_json[0].get("modelId")
unit_rssi = unit_data_json[0].get("rssi")
unit_power_ordinal = unit_attributes_json.get("A02")
unit_power_text = list(POWER.keys())[list(POWER.values()).index(unit_power_ordinal)]
if unit_power_text == "OFF" :
unit_is_off = True
else :
unit_is_off = False
# this is the time the unit last sent its status up to the web server
unit_update_time_gmt_ts = int(unit_data_json[0].get("utcTimestamp"))
unit_update_time_local = datetime.fromtimestamp(unit_update_time_gmt_ts).strftime('%Y-%m-%d %H:%M')
update_age_timedelta = datetime.fromtimestamp(unit_status_retrieval_ts) - datetime.fromtimestamp(unit_update_time_gmt_ts)
update_age_text = str(update_age_timedelta)
# if the unit is powered off, none of status is valid
if unit_is_off :
air_quality_ordinal = "-1"
air_quality_text = "UNKNOWN"
air_quality_value = "-1"
unit_sleeping_text = "UNKNOWN"
unit_plasmawave_ordinal = "-1"
unit_plasmawave_text = "UNKNOWN"
unit_mode_ordinal = "-1"
unit_mode_text = "UNKNOWN"
unit_fan_speed_ordinal = "-1"
unit_fan_speed_text = "UNKNOWN"
unit_filter_hours = "-1"
unit_ambient_light = "-1"
else :
air_quality_ordinal = unit_attributes_json.get("S07")
# do a value loop to find they key
air_quality_text = list(AIR_QUALITY.keys())[list(AIR_QUALITY.values()).index(air_quality_ordinal)]
air_quality_value = unit_attributes_json.get("S08")
# fan speed also signals the unit is sleeping
if unit_attributes_json.get("A04") == "06" :
unit_sleeping_text = "YES"
else :
unit_sleeping_text = "NO"
unit_plasmawave_ordinal = unit_attributes_json.get("A07")
unit_plasmawave_text = list(PLASMAWAVE.keys())[list(PLASMAWAVE.values()).index(unit_plasmawave_ordinal)]
unit_mode_ordinal = unit_attributes_json.get("A03")
unit_mode_text = list(OPERATION_MODE.keys())[list(OPERATION_MODE.values()).index(unit_mode_ordinal)]
unit_fan_speed_ordinal = unit_attributes_json.get("A04")
unit_fan_speed_text = list(FAN_SPEED.keys())[list(FAN_SPEED.values()).index(unit_fan_speed_ordinal)]
unit_filter_hours = unit_attributes_json.get("A21")
unit_ambient_light = unit_attributes_json.get("S14")
# if the unit is sleeping, none of status is valid
if unit_sleeping_text == "YES" :
# air_quality_ordinal = "-1"
# air_quality_text = "UNKNOWN"
# air_quality_value = "-1"
unit_plasmawave_ordinal = "-1"
unit_plasmawave_text = "UNKNOWN"
unit_mode_ordinal = "-1"
unit_mode_text = "UNKNOWN"
# unit_filter_hours = "-1"
# unit_ambient_light = "-1"
unit_fan_speed_ordinal = "-1"
unit_fan_speed_text = "UNKNOWN"
# create dictionary to be converted to JSON string
message = {"timestamp": "{:d}".format(unit_status_retrieval_ts)}
message["unit_update_ts"] = str(unit_update_time_gmt_ts)
message["update_age_text"] = update_age_text
message["unit_model"] = unit_model
message["home"] = UNITS_BY_MAC[unit_mac]["home"]
message["room"] = UNITS_BY_MAC[unit_mac]["room"]
message["unit_power_ordinal"] = str(int(unit_power_ordinal))
message["power_text"] = unit_power_text
message["unit_sleeping_text"] = unit_sleeping_text
message["air_quality_ordinal"] = str(int(air_quality_ordinal))
message["air_quality_text"] = air_quality_text
message["air_quality_value"] = air_quality_value
message["unit_plasmawave_ordinal"] = str(int(unit_plasmawave_ordinal))
message["unit_plasmawave_text"] = unit_plasmawave_text
message["unit_mode_ordinal"] = str(int(unit_mode_ordinal))
message["unit_mode_text"] = unit_mode_text
message["unit_fan_speed_ordinal"] = str(int(unit_fan_speed_ordinal))
message["unit_fan_speed_text"] = unit_fan_speed_text
message["unit_filter_hours"] = unit_filter_hours
message["unit_ambient_light"] = unit_ambient_light
message["unit_rssi"] = unit_rssi
message["unit_body_json"] = unit_body_json
# Publish message to topic
# create JSON string
# doing the json.dumps forces single quotes to double quotes, which json likes better
message_to_publish = json.dumps(message)
mqttc.publish(MQTT_TOPIC_BASE + unit_mac_address + MQTT_STATUS_TOPIC, message_to_publish)
my_logger.debug("publishing on topic : |" + MQTT_TOPIC_BASE + unit_mac_address + MQTT_STATUS_TOPIC + "|")
my_logger.debug("publishing message : |" + str(message_to_publish) + "|")
# don't call api too quickly
time.sleep(API_DELAY_SECONDS)
return
# using the timeloop scheduling tool, update all the units status from winix cloud on a regular basis
@tl.job(interval=timedelta(minutes=CHECK_PERIOD_MINUTES))
def periodic_update_units():
# queue up a request for the current status of each unit
for unit in UNITS :
my_logger.debug("periodic update, queueing status update request for : " + UNITS[unit]['mac_address'])
queue_unit_request_update.put(UNITS[unit]['mac_address'])
return
def main():
# keep track of transition to new day at midnight local time
# at rollover, reset the tracking of duplicate incident id
current_day = datetime.now().timetuple().tm_yday
try :
# # connect to MQTT server
# mqttc = mqtt.Client(PROGRAM_NAME) # Create instance of client with client ID
# mqttc.connect(MQTT_SERVER, 1883) # Connect to (broker, port, keepalive-time)
# Add message callbacks that will only trigger on a specific subscription match.
mqttc.message_callback_add(MQTT_TOPIC_BASE + "#", message_to_or_from_unit)
mqttc.subscribe(MQTT_TOPIC_BASE + "#", 0)
message = {"timestamp": "{:d}".format(int(datetime.now().timestamp()))}
message["program_version"] = PROGRAM_NAME + " Version : " + VERSION_MAJOR + "." + VERSION_MINOR
message["status"] = "START"
message["unit_check_interval"] = CHECK_PERIOD_MINUTES
mqttc.publish(MQTT_TOPIC_BASE + "$SYS/STATUS", json.dumps(message))
my_logger.info("Program start : " + PROGRAM_NAME + " Version : " + VERSION_MAJOR + "." + VERSION_MINOR)
# Start mqtt
mqttc.loop_start()
# get the initial state of all the winix units from winix cloud
periodic_update_units()
# start timeloop thread to update units on periodic basis
tl.start()
# loop forever waiting for keyboard interrupt, seeing if there are unit update requests queued
while True :
# check if it is a new day, if so clear out the record of duplicate incidents published during prior day
# publish to MQTT a stat about how many unique incidents were published in prior day
if current_day != datetime.now().timetuple().tm_yday :
my_logger.info("24 hour rollover")
current_day = datetime.now().timetuple().tm_yday
try :
unit_mac = queue_unit_request_update.get(block=False)
my_logger.debug("queue request for :" + unit_mac + " requesting update")
get_unit_update(unit_mac)
except queue.Empty :
# break, continue and pass. pass seems the proper action for nothing in queue
pass
time.sleep(1)
# end loop forever
except KeyboardInterrupt :
tl.stop()
message = {"timestamp": "{:d}".format(int(datetime.now().timestamp()))}
message["program_version"] = PROGRAM_NAME + " Version : " + VERSION_MAJOR + "." + VERSION_MINOR
message["status"] = "STOP"
mqttc.publish(MQTT_TOPIC_BASE + "$SYS/STATUS", json.dumps(message))
mqttc.disconnect()
mqttc.loop_stop()
my_logger.info("Keyboard interrupt.")
# sys.exit(0)
except :
tl.stop()
my_logger.critical("Unhandled error : " + traceback.format_exc())
sys.exit(1)
# proper exit
my_logger.info("Program end : " + PROGRAM_NAME + " Version : " + VERSION_MAJOR + "." + VERSION_MINOR)
sys.exit(0)
if __name__ == '__main__':
main()
# if __name__ == '__main__':