#!/usr/bin/env python
"""
APC UPS Monitoring
"""
"""
<plugin key="APCUPS" name="APC UPS" version="0.1" author="Joerek van Gaalen">
<params>
<param field="Address" label="Your APC UPS Address" width="200px" required="true" default="127.0.0.1"/>
<param field="Port" label="Port" width="40px" required="true" default="3551"/>
<param field="Mode1" label="Reading Interval (sec)" width="40px" required="true" default="10" />
<param field="Mode2" label="apcaccess path" width="200px" required="true" default="/sbin/apcaccess" />
</params>
</plugin>
"""
import Domoticz
import subprocess #For OS calls
values = {
'STATUS': {'dname': 'Status', 'dunit': 1, 'dtype':243, 'dsubtype':19},
'LINEV': {'dname': 'Line voltage', 'dunit': 2, 'dtype':243, 'dsubtype':8},
'LOADPCT': {'dname': 'Load percentage', 'dunit': 3, 'dtype':243, 'dsubtype':6},
'BCHARGE': {'dname': 'Battery charge level', 'dunit': 4, 'dtype':243, 'dsubtype':6},
'MODEL': {'dname': 'Model', 'dunit': 5, 'dtype':243, 'dsubtype':19},
'SERIALNO': {'dname': 'Serial Number', 'dunit': 6, 'dtype':243, 'dsubtype':19},
'BATTV': {'dname': 'Battery voltage', 'dunit': 7, 'dtype':243, 'dsubtype':8},
'NOMBATTV': {'dname': 'Nominal battery voltage', 'dunit': 8, 'dtype':243, 'dsubtype':8},
'BATTDATE': {'dname': 'Battery date', 'dunit': 9, 'dtype':243, 'dsubtype':19},
'SELFTEST': {'dname': 'Date of last self test', 'dunit': 10, 'dtype':243, 'dsubtype':19},
'LASTXFER': {'dname': 'Reason for last transfer to battery', 'dunit': 11, 'dtype':243, 'dsubtype':19},
'NOMPOWER': {'dname': 'Nominal UPS power output', 'dunit': 12, 'dtype':243, 'dsubtype':31, 'options':'1;Watt'},
'TIMELEFT': {'dname': 'Time left on battery', 'dunit': 13, 'dtype':243, 'dsubtype':31, 'options':'1;minutes'},
'NUMXFERS': {'dname': 'Number of transfers to battery', 'dunit': 14, 'dtype':243, 'dsubtype':31, 'options':'1;times'},
'TONBATT': {'dname': 'Time on battery', 'dunit': 15, 'dtype':243, 'dsubtype':31, 'options':'1;minutes'},
'CUMONBATT': {'dname': 'Cumulative time on battery', 'dunit': 16, 'dtype':243, 'dsubtype':31, 'options':'1;minutes'},
}
def onStart():
Domoticz.Log("Domoticz APC UPS plugin start")
if len(Devices) != len(values):
for key in values:
try:
Domoticz.Device(Name=values[key]['dname'], Unit=values[key]['dunit'], Type=values[key]['dtype'], Subtype=values[key]['dsubtype'], Used=1, Options=values[key]['options']).Create()
except:
Domoticz.Device(Name=values[key]['dname'], Unit=values[key]['dunit'], Type=values[key]['dtype'], Subtype=values[key]['dsubtype'], Used=1).Create()
Domoticz.Heartbeat(int(Parameters["Mode1"]))
def onHeartbeat():
try:
res = str(subprocess.check_output([Parameters["Mode2"], '-u', '-h', Parameters["Address"] + ':' + Parameters["Port"]]))
battery_values = {}
for line in res.strip().split('\\n'):
(key,spl,val) = line.partition(': ')
key = key.rstrip() #Strip spaces right of text
val = val.strip() #Remove outside spaces
battery_values[key] = float(val) if val.replace('.', '', 1).isdigit() else val
batterylevel = int(str(battery_values.get('BCHARGE', -1)).split('.')[0])
for key, val in battery_values.items():
if key in values:
#Domoticz.Log("{} {}".format(key,val))
iUnit = values[key]['dunit']
curval = Devices[iUnit].sValue
if ( str(val) != curval ):
if batterylevel >= 0:
Devices[iUnit].Update(nValue=0, sValue=str(val), BatteryLevel=batterylevel)
else:
Devices[iUnit].Update(0, str(val))
except Exception as err: