// Licensed to the .NET Foundation under one or more agreements.
// The .NET Foundation licenses this file to you under the MIT license.
using System;
using UnitsNet;
namespace Iot.Device.Ld2410
{
/// <summary>
/// Defines a specific gate's sensitivity configurations.
/// </summary>
public sealed class GateConfiguration
{
/// <summary>
/// The distance, in centimeters, per each radar distance gate.
/// </summary>
public static readonly Length DistancePerGateInCm = Length.FromCentimeters(75);
private Ratio _restSensitivity;
/// <summary>
/// Gets the gate number of this configuration instance.
/// </summary>
public byte Gate { get; }
/// <summary>
/// Gets or sets the motion sensitivity threshold. Any target with a movement "energy" greater than the specified range will be detected, otherwise it will be ignored.
/// Setting a gate's sensitivity to 100 will effectively disable detection of movement within that distance gate.
/// This can enable fine control over the range of distance to detect movements in.
/// For example, All gates except 4 and 7 are set to 100. This means movement will only be detected in gates 4 and 5 (between 3 meters and 5.25 meters from the radar).
/// </summary>
/// <remarks>There is no defined unit of measurement for this and should be treated as a percentage. It is recommended to experiment with the values to find the right threshold for the use-case at hand.</remarks>
public Ratio MotionSensitivity { get; set; }
/// <summary>
/// Gets or sets the resting sensitivity threshold. Any target without movement "energy" (resting) greater than the specified range will be detected, otherwise it will be ignored.
/// Setting a gate's sensitivity to 100 will effectively disable detection of resting targets within that distance gate.
/// This can enable fine control over the range of distance to detect resting targets in.
/// For example, All gates except 4 and 7 are set to 100. This means resting targets will only be detected in gates 4 and 5 (between 3 meters and 5.25 meters from the radar).
/// </summary>
/// <remarks>There is no defined unit of measurement for this and should be treated as a percentage. It is recommended to experiment with the values to find the right threshold for the use-case at hand.</remarks>
/// <exception cref="InvalidOperationException">Cannot set this value for Gate 0 and 1.</exception>
public Ratio RestSensitivity
{
get => _restSensitivity;
set
{
if (Gate == 0 || Gate == 1)
{
throw new InvalidOperationException();
}
_restSensitivity = value;
}
}
/// <summary>
/// Gets the detection distance of this gate.
/// </summary>
public Length DetectionDistance
=> Length.FromCentimeters(Gate * DistancePerGateInCm.Centimeters);
/// <summary>
/// Initializes a new instance of the <see cref="GateConfiguration"/> class with the specified gate number.
/// </summary>
/// <param name="gate">The gate number to initialize the <see cref="GateConfiguration"/> class for.</param>
public GateConfiguration(byte gate)
{
Gate = gate;
}
#if DEBUG
/// <inheritdoc/>
public override string ToString()
{
return $"Gate: {Gate}, Motion Sensitivity: {MotionSensitivity}, Rest Sensitivity: {RestSensitivity}";
}
#endif
}
}