Notifications
You must be signed in to change notification settings - Fork 12
/
CommFacilitator.cs
686 lines (649 loc) · 36.2 KB
/
CommFacilitator.cs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
using System;
using System.Collections.Generic;
using System.Data;
using System.Data.SqlClient;
using System.Text;
using static UniversaLIS.UniversaLIService;
// TODO: Escape special characters in message fields, remove any delimiter characters within field contents.
// TODO: Consider field mappings when constructing SQL commands.
namespace UniversaLIS
{
public class CommFacilitator
{
private bool bInterFrame = false;
private readonly IPortAdapter ComPort;
private readonly IPortSettings portSettings;
internal UniversaLIService service;
public CountdownTimer ContentTimer { get; set; } = new CountdownTimer(-1);
public int CurrentFrameCounter { get; set; }
public Message CurrentMessage { get; set; }
private string? intermediateFrame;
public int NumNAK { get; set; } = 0;
public Queue<Message> OutboundMessageQueue { get; set; } = new Queue<Message>();
public CountdownTimer RcvTimer { get; set; }
public CountdownTimer TransTimer { get; set; }
private readonly System.Timers.Timer idleTimer = new System.Timers.Timer();
internal string? receiver_id;
internal int frameSize;
internal string? password;
public CountdownTimer BusyTimer { get; set; } = new CountdownTimer(-1);
public LisCommState CommState { get; set; }
internal string GetPortDetails()
{
return portSettings.GetPortDetails();
}
public void Send(string messageText)
{
ComPort.Send(messageText);
}
// Use this string when setting up internal database connection functions.
// readonly string connString = UniversaLIService.YamlSettings?.ServiceConfig?.SqlitePath!;
public CommFacilitator(Serial serialSettings, UniversaLIService LIService)
{
service = LIService;
portSettings = serialSettings;
if (serialSettings.UseLegacyFrameSize)
{
frameSize = 240;
}
else
{
frameSize = 63993;
}
password = serialSettings.Password;
try
{
// Set the serial port properties and try to open it.
receiver_id = serialSettings.ReceiverId;
ComPort = new CommPort(serialSettings, this);
CommState = new LisCommState(this);
RcvTimer = new CountdownTimer(-1, ReceiptTimedOut);
TransTimer = new CountdownTimer(-1, TransactionTimedOut);
CurrentMessage = new Message(this);
// Set the handler for the DataReceived event.
ComPort.PortDataReceived += CommPortDataReceived!;
ComPort.Open();
AppendToLog($"Port opened: {serialSettings.Portname}");
idleTimer.AutoReset = true;
idleTimer.Elapsed += new System.Timers.ElapsedEventHandler(IdleTime);
if (serialSettings.AutoSendOrders > 0)
{
idleTimer.Elapsed += WorklistTimedEvent;
idleTimer.Interval = serialSettings.AutoSendOrders;
}
else
{
idleTimer.Interval = 10000;
}
idleTimer.Start();
}
catch (Exception ex)
{
service.HandleEx(ex);
throw;
}
}
public CommFacilitator(Tcp tcpSettings, UniversaLIService LIService)
{
service = LIService;
CommState = new LisCommState(this);
RcvTimer = new CountdownTimer(-1, ReceiptTimedOut);
TransTimer = new CountdownTimer(-1, TransactionTimedOut);
portSettings = tcpSettings;
if (tcpSettings.UseLegacyFrameSize)
{
frameSize = 240;
}
else
{
frameSize = 63993;
}
password = tcpSettings.Password;
try
{
// Set the port properties and try to open it.
receiver_id = tcpSettings.ReceiverId;
ComPort = new TcpPort(tcpSettings);
// Set the handler for the DataReceived event.
ComPort.PortDataReceived += CommPortDataReceived!;
CurrentMessage = new Message(this);
ComPort.Open();
AppendToLog($"Socket opened: {tcpSettings.Socket}");
idleTimer.AutoReset = true;
idleTimer.Elapsed += new System.Timers.ElapsedEventHandler(IdleTime);
if (tcpSettings.AutoSendOrders > 0)
{
idleTimer.Elapsed += WorklistTimedEvent;
}
idleTimer.Start();
}
catch (Exception ex)
{
service.HandleEx(ex);
throw;
}
}
public void Close()
{
try
{
idleTimer.Stop();
idleTimer.Dispose();
/* TODO: Update the request table so that any unsent messages will be sent next time the service runs.
* This may require adding an ID field to the Order class.
*/
while (OutboundMessageQueue.Count > 0)
{
Message message = OutboundMessageQueue.Dequeue();
using (SqlConnection conn = new SqlConnection(UniversaLIService.YamlSettings?.ServiceConfig?.ConnectionString))
{
foreach (Patient patientItem in message.Patients)
{
foreach (Order orderItem in patientItem.Orders)
{
using (SqlCommand command = conn.CreateCommand())
{
command.CommandText = "UPDATE IMM_RequestOrders SET PendingSending = 1 WHERE ReqOrderID = @OrderID";
command.Parameters.AddWithValue("@OrderID", orderItem.OrderID);
command.ExecuteNonQuery();
}
}
}
}
}
ComPort.Close();
AppendToLog($"Port closed: {ComPort.PortName}");
}
catch (Exception ex)
{
service.HandleEx(ex);
throw;
}
}
void CommPortDataReceived(object sender, EventArgs e)
{
/* When new data is received,
* parse the message line-by-line.
*/
IPortAdapter port = (IPortAdapter)sender;
StringBuilder buffer = new StringBuilder();
try
{
idleTimer.Stop();
#if DEBUG
System.Diagnostics.Stopwatch stopwatch = System.Diagnostics.Stopwatch.StartNew(); // This stopwatch is an attempt at performance optimization.
#endif
/* There are a few messages that won't end in a NewLine,
* so we have to read one character at a time until we run out of them.
*/
// Read one char at a time until the ReadChar times out.
try
{
buffer.Append(port.ReadChars());
}
catch (Exception)
{
#if DEBUG
stopwatch.Stop();
#endif
}
#if DEBUG
UniversaLIService.AppendToLog($"Elapsed port read time: {stopwatch.ElapsedMilliseconds}");
#endif
UniversaLIService.AppendToLog($"In: \t{buffer}");
CommState.RcvInput(buffer.ToString());
idleTimer.Start();
}
catch (Exception ex)
{
service.HandleEx(ex);
throw;
}
}
private void IdleTime(object? o, System.Timers.ElapsedEventArgs elapsedEvent)
{
idleTimer.Stop();
CommState.IdleCheck();
idleTimer.Start();
}
public void ParseMessageLine(string messageLine)
{
// Parse each line of the incoming message as it's received.
// This is done by assembling the CurrentMessage (a MessageBody) with Header, Patient, Order, Result, etc., records.
// Receiving a Header record triggers instantiation of a new MessageBody.
// As each subsequent component is received, add it to the CurrentMessage.
// The message will be processed by the CommPortDataReceived method when the EOT signal is received.
if (messageLine.Length < 5)
{
UniversaLIService.AppendToLog($"Invalid message: {messageLine}");
return;
}
int position = messageLine.IndexOf(Constants.ETB);
if (position >= 0)
{
bInterFrame = true;
if (intermediateFrame?.Length > 2)
{
intermediateFrame += messageLine.Substring(2, position);
}
else
{
intermediateFrame += messageLine.Substring(0, position);
}
return; // Don't process yet.
}
else
{
if (bInterFrame) // If it's an intermediate frame, trim off the frame number and concatenate with previous frame.
{
intermediateFrame += messageLine.Substring(2, position);
messageLine = intermediateFrame;
intermediateFrame = "";
bInterFrame = false;
}
}
switch (messageLine.Substring(2, 1))
{
case "H": // New message header.
CurrentMessage = new Message(messageLine);
break;
case "P": // Patient record.
CurrentMessage.Patients.Add(new Patient(messageLine));
break;
case "O": // Order record.
CurrentMessage.Patients[^1].Orders.Add(new Order(messageLine));
break;
case "R": // Result record.
CurrentMessage.Patients[^1].Orders[^1].Results.Add(new Result(messageLine));
break;
case "L": // Terminator record.
if (messageLine.Substring(5, 1) == Constants.CR)
{
CurrentMessage.Terminator = 'N';
}
else
{
CurrentMessage.Terminator = messageLine[5];
}
break;
case "Q": // Host Query record.
CurrentMessage.Queries.Add(new Query(messageLine));
break;
default:
break;
}
}
public void ProcessMessage(Message message)
{
/* The message is complete. Deal with it. */
#if DEBUG
UniversaLIService.AppendToLog("Processing message.");
#endif
if (message == null)
{
UniversaLIService.AppendToLog("MessageBody is null!");
return;
}
/* First, check to see whether the LIS is sending or receiving the message.
* Do this by comparing the [Receiver ID] and [Sender ID] header fields.
* The one that matches the value defined in the Settings file will tell us
* how to handle the rest of the message.
*/
string[] headerFields = message.MessageHeader.Split('|');
if (headerFields[4] == UniversaLIService.YamlSettings?.ServiceConfig?.LisId)
{
// Message is outgoing. Queue it up to be sent to the IMMULITE.
#if DEBUG
UniversaLIService.AppendToLog("Outgoing message, adding to queue...");
#endif
OutboundMessageQueue.Enqueue(message);
}
else if (headerFields[4] == receiver_id)
{
// Message is incoming. Add the contents to the appropriate database tables.
/* For our purposes, there are two primary incoming message types
* (from the IMMULITE to the LIS):
* 1. [Q]uery messages, and
* 2. [P]atient-[O]rder-[R]esult messages.
*/
if (message.Queries.Count > 0) // This one is a query.
{
foreach (var query in message.Queries)
{
UniversaLIService.AppendToLog("Processing query.");
ProcessQuery(query);
}
}
else
{
int pID;
int oID;
#if DEBUG
UniversaLIService.AppendToLog("Connecting to database.");
#endif
// This is where we have to connect to the database.
// TODO: Support internal database with SQLite
using (SqlConnection conn = new SqlConnection(UniversaLIService.YamlSettings?.ServiceConfig?.ConnectionString))
{
conn.Open();
#if DEBUG
UniversaLIService.AppendToLog("Database connection open.");
#endif
foreach (var patient in message.Patients)
{
/* * Patient fields: * *
* Note: Fields marked with "=/=" are listed in the Siemens interface specification as not officially supported.
* These fields may or may not actually be functional.
* 0 Record Type
* 1 Sequence # Definition
* 2 Practice Assigned Patient ID
* 3 Laboratory Assigned Patient ID =/=
* 4 Patient ID =/=
* 5 Patient Name
* 6 Mother's Maiden Name =/=
* 7 Birthdate
* 8 Patient's Sex
* 9 Patient Race-Ethnic Origin =/=
*10 Patient's Address =/=
*11 Reserved Field =/=
*12 Patient's Phone# =/=
*13 Attending Physician ID =/=
*14 Special Field 1 =/=
*15 Special Field 2 =/=
*16 Patient Height =/=
*17 Patient Weight =/=
*18 Patients Known or Suspected Diagnosis =/=
*19 Patient active medications =/=
*20 Patients Diet =/=
*21 Practice Field #1 =/=
*22 Practice Field #2 =/=
*23 Admission and Discharge Dates =/=
*24 Admission Status =/=
*25 Location =/=
*26 Nature of Alternative Diagnostic Code and Classification =/=
*27 Alternative Diagnostic Code and Classification =/=
*28 Patient Religion =/=
*29 Marital Status =/=
*30 Isolation Status =/=
*31 Language =/=
*32 Hospital Service =/=
*33 Hospital Institution =/=
*34 Dosage Category =/=
*/
UniversaLIService.AppendToLog("Adding patient.");
// Transmit a patient record to the IMM_Patients table,
// grab the row ID, and use it to add order records to the IMM_Orders table.
using (SqlCommand command = new SqlCommand("spIMMPatient", conn))
{
command.CommandType = CommandType.StoredProcedure;
_ = command.Parameters.AddWithValue("@Patient_ID", patient.Elements["Patient ID"]);
_ = command.Parameters.AddWithValue("@Patient_Name", patient.Elements["Patient Name"]);
_ = command.Parameters.AddWithValue("@Patient_DOB", patient.Elements["BirthDate"]);
_ = command.Parameters.AddWithValue("@Patient_Sex", patient.Elements["Patient Sex"]);
_ = command.Parameters.AddWithValue("@Physician_Name", patient.Elements["Attending Physician ID"]);
SqlParameter sqlOutParameter = new SqlParameter("@ID", SqlDbType.Int)
{
Direction = ParameterDirection.Output
};
_ = command.Parameters.Add(sqlOutParameter);
_ = command.ExecuteNonQuery();
pID = int.Parse(command.Parameters["@ID"].Value.ToString() ?? "0");
}
foreach (var order in patient.Orders)
{
/*
* * Order Fields: * *
* Note: Fields marked with "=/=" are listed in the Siemens interface specification as not officially supported.
* These fields may or may not actually be functional.
* 0 Record Type (O)
* 1 Sequence#
* 2 Specimen ID (Accession#)
* 3 Instrument Specimen ID
* 4 Universal Test ID
* 5 Priority
* 6 Order Date/Time
* 7 Collection Date/Time
* 8 Collection End Time
* 9 Collection Volume
* 10 Collector ID
* 11 Action Code
* 12 Danger Code
* 13 Relevant Clinical Info
* 14 Date/Time Specimen Received
* 15 Specimen Descriptor,Specimen Type,Specimen Source
* 16 Ordering Physician
* 17 Physician's Telephone Number
* 18 User Field No.1
* 19 User Field No.2
* 20 Lab Field No.1
* 21 Lab Field No.2
* 22 Date/Time results reported or last modified
* 23 Instrument Charge to Computer System
* 24 Instrument Section ID
* 25 Report Types
* 26 Reserved Field
* 27 Location or ward of Specimen Collection
* 28 Nosocomial Infection Flag
* 29 Specimen Service
* 30 Specimen Institution
*/
UniversaLIService.AppendToLog("Adding order.");
using (SqlCommand command = new SqlCommand("spIMMOrder", conn))
{
command.CommandType = CommandType.StoredProcedure;
_ = command.Parameters.AddWithValue("@Patient_ID", pID);
_ = command.Parameters.AddWithValue("@Sample_Number", order.Elements["Specimen ID (Accession#)"]);
_ = command.Parameters.AddWithValue("@Test_Code", order.Elements["Universal Test ID"]);
_ = command.Parameters.AddWithValue("@Priority", order.Elements["Priority"]);
_ = command.Parameters.AddWithValue("@Order_DateTime", order.Elements["Order Date/Time"]);
_ = command.Parameters.AddWithValue("@Collection_DateTime", order.Elements["Collection Date/Time"]);
SqlParameter sqlOutParameter = new SqlParameter("@ID", SqlDbType.Int)
{
Direction = ParameterDirection.Output
};
_ = command.Parameters.Add(sqlOutParameter);
_ = command.ExecuteNonQuery();
oID = int.Parse(command.Parameters["@ID"].Value.ToString() ?? "0");
}
// Use the row ID from each of those order records to add
// result records to the IMM_Results table for each Patient.Order.Result in the message.
foreach (var result in order.Results)
{
/* * Result Fields: * *
* Note: Fields marked with "=/=" are listed in the Siemens interface specification as not officially supported.
* These fields may or may not actually be functional.
* 0 Record Type (R)
* 1 Sequence #
* 2 Universal Test ID
* 3 Data (result)
* 4 Units
* 5 ReferenceRanges
* 6 Result abnormal flags
* 7 Nature of Abnormality Testing
* 8 Result Status
* 9 Date of change in instruments normal values or units
* 10 Operator ID
* 11 Date\Time Test Started
* 12 Date\Time Test Completed
* 13 Instrument ID
*/
UniversaLIService.AppendToLog("Adding result.");
using (SqlCommand command = new SqlCommand("spIMMResult", conn))
{
command.CommandType = CommandType.StoredProcedure;
_ = command.Parameters.AddWithValue("@Order_ID", oID);
_ = command.Parameters.AddWithValue("@Test_Code", result.Elements["Universal Test ID"]);
_ = command.Parameters.AddWithValue("@ResultValue", result.Elements["Data (result)"]);
_ = command.Parameters.AddWithValue("@ResultUnits", result.Elements["Units"]);
_ = command.Parameters.AddWithValue("@RefRanges", result.Elements["Reference Ranges"]);
_ = command.Parameters.AddWithValue("@AbnormalFlags", result.Elements["Result abnormal flags"]);
_ = command.Parameters.AddWithValue("@AbnormalityTesting", result.Elements["Nature of Abnormality Testing"]);
_ = command.Parameters.AddWithValue("@ResultStatus", result.Elements["Result Status"]);
_ = command.Parameters.AddWithValue("@Operator", result.Elements["Operator ID"]);
string dtStart = result.Elements["Date/Time Test Started"];
DateTime start = new DateTime(Convert.ToInt32(dtStart.Substring(0, 4)), Convert.ToInt32(dtStart.Substring(4, 2)), Convert.ToInt32(dtStart.Substring(6, 2)), Convert.ToInt32(dtStart.Substring(8, 2)), Convert.ToInt32(dtStart.Substring(10, 2)), Convert.ToInt32(dtStart.Substring(12, 2)));
_ = command.Parameters.AddWithValue("@TestStarted", start);
string dtEnd = result.Elements["Date/Time Test Completed"];
DateTime end = new DateTime(Convert.ToInt32(dtEnd.Substring(0, 4)), Convert.ToInt32(dtEnd.Substring(4, 2)), Convert.ToInt32(dtEnd.Substring(6, 2)), Convert.ToInt32(dtEnd.Substring(8, 2)), Convert.ToInt32(dtEnd.Substring(10, 2)), Convert.ToInt32(dtEnd.Substring(12, 2)));
_ = command.Parameters.AddWithValue("@TestCompleted", end);
char[] trimmings = { '\x03', '\x0D' };
_ = command.Parameters.AddWithValue("@Instrument_ID", result.Elements["Instrument ID"].Trim(trimmings));
_ = command.ExecuteNonQuery();
}
}
}
}
}
}
}
else
{
// This message is invalid!
UniversaLIService.AppendToLog($"Invalid message header! {message.MessageHeader}");
throw new ArgumentException($"Invalid message header: {message.MessageHeader}");
}
}
private void ProcessQuery(Query query)
{
// Extract Sample Number from the query string.
string SampleNumber = query.Elements["Starting Range"].Trim('^');
string testID = query.Elements["Test ID"];
// SendPatientOrders for the requested SampleNumber/testID.
_ = SendPatientOrders(SampleNumber, testID);
}
public void ReceiptTimedOut(object? sender, EventArgs e)
{
CommState.RcvTimeout();
}
private int SendPatientOrders(string SampleNumber, string testID)
{
bool isQuery = true;
// If no SampleNumber is provided, use the % wildcard to get all pending orders.
if (SampleNumber.Length == 0)
{
SampleNumber = "%";
}
if (SampleNumber == "%")
{
isQuery = false;
}
// Query the database for [P]atient and [O]rder records for the sample.
using (SqlConnection conn = new SqlConnection(UniversaLIService.YamlSettings?.ServiceConfig?.ConnectionString))
{
conn.Open();
int orderCount;
using (SqlCommand sqlCommand = conn.CreateCommand())
{ // Check to see how many orders are pending for the sample.
sqlCommand.CommandText = "SELECT COUNT(IMM_RequestOrders.ReqOrderID) AS OrderCount FROM IMM_RequestOrders WHERE (IMM_RequestOrders.Sample_Number LIKE @SampleNumber) AND (IMM_RequestOrders.PendingSending = 1)";
_ = sqlCommand.Parameters.AddWithValue("@SampleNumber", SampleNumber);
orderCount = (int)sqlCommand.ExecuteScalar();
}
if (orderCount == 0)
{ // No pending orders.
if (isQuery)
{
// Reply with a "no information available from last query" message (terminator = "I")
UniversaLIService.AppendToLog($"No information available from last query (sample number: {SampleNumber})");
Message messageBody = new Message(this)
{
Terminator = 'I'
};
ProcessMessage(messageBody);
}
// Exit function.
return orderCount;
}
Message responseMessage = new Message(this);
int patientCount;
using (SqlCommand sqlCommand = conn.CreateCommand())
{ // Check to see how many patients are associated with the sample.
sqlCommand.CommandText = "SELECT COUNT(RequestPID) AS PatientCount FROM (SELECT RequestPID FROM vwPendingRequests WHERE (Sample_Number LIKE @SampleNumber) GROUP BY RequestPID) AS tmp";
_ = sqlCommand.Parameters.AddWithValue("@SampleNumber", SampleNumber);
patientCount = (int)sqlCommand.ExecuteScalar();
}
string sqlMainQuery = "SELECT * FROM vwPendingRequests WHERE Patient_Name LIKE @Patient_Name AND Test_ID LIKE @Test_ID AND Sample_Number LIKE @Sample_Number;";
string sqlPatientQuery = "SELECT Patient_ID, Patient_Name, BirthDate, Patient_Sex FROM vwPendingRequests WHERE (Sample_Number LIKE @Sample_Number) AND (Test_ID LIKE @Test_ID) GROUP BY Patient_ID, Patient_Name, BirthDate, Patient_Sex";
using (SqlCommand command = conn.CreateCommand())
{
command.CommandText = sqlPatientQuery;
command.Parameters.AddWithValue("@Sample_Number", SampleNumber);
if (testID == "ALL")
{
testID = "%";
}
command.Parameters.AddWithValue("@Test_ID", testID);
SqlDataReader patientReader = command.ExecuteReader();
if (!patientReader.HasRows)
{
return 0;
}
else
{
while (patientReader.Read())
{
responseMessage.Patients.Add(new Patient($"|{responseMessage.Patients.Count + 1}|{patientReader["Patient_ID"]}|||{patientReader["Patient_Name"]}||{patientReader["BirthDate"]}|{patientReader["Patient_Sex"]}||||||||||||||||||||||||||"));
}
}
patientReader.Close();
}
foreach (var patient in responseMessage.Patients)
{
string? requestID = "";
using (SqlCommand orderCommand = conn.CreateCommand())
{
orderCommand.CommandText = sqlMainQuery;
orderCommand.Parameters.AddWithValue("@Patient_Name", patient.Elements["Patient Name"]);
orderCommand.Parameters.AddWithValue("@Sample_Number", SampleNumber);
if (testID == "ALL")
{
testID = "%";
}
orderCommand.Parameters.AddWithValue("@Test_ID", testID);
SqlDataReader orderReader = orderCommand.ExecuteReader();
while (orderReader.Read())
{
patient.Orders.Add(new Order($"|{patient.Orders.Count + 1}|{orderReader["Sample_Number"]}||{orderReader["Test_ID"]}|{orderReader["Priority"]}|{orderReader["Order_DateTime"]}|{orderReader["Collection_DateTime"]}|||||||||||{orderReader["RequestPID"]}||||||||||||", (int)orderReader["ReqOrderID"]));
requestID = orderReader["RequestPID"].ToString();
}
orderReader.Close();
}
using (SqlCommand command = conn.CreateCommand())
{
command.CommandText = "UPDATE IMM_RequestOrders SET PendingSending = 0 WHERE RequestPID = @RequestID";
command.Parameters.AddWithValue("@RequestID", requestID);
command.ExecuteNonQuery();
}
}
if (isQuery)
{
responseMessage.Terminator = 'F';
}
else
{
responseMessage.Terminator = 'N';
}
ProcessMessage(responseMessage);
return orderCount;
}
}
public void TransactionTimedOut(object? sender, EventArgs e)
{
CommState.TransTimeout();
}
public void WorklistTimedEvent(object? source, System.Timers.ElapsedEventArgs e)
{
/* If the outStringQueue is empty, SendPatientOrders for all pending orders
* and their respective patient records to send them all to the IMMULITE.
*/
// Stop the timer while any pending requests are sent.
idleTimer.Stop();
// Until the program is more stable, only add to the queue when it's empty.
if (OutboundMessageQueue.Count == 0)
{
SendPatientOrders("%", "ALL");
}
// Now that all pending requests have been sent, restart the timer.
idleTimer.Start();
}
}
}