Notifications
You must be signed in to change notification settings - Fork 12
/
Order.cs
129 lines (120 loc) · 6.34 KB
/
Order.cs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
using System;
using System.Collections.Generic;
namespace UniversaLIS
{
public class Order
{
public Dictionary<string, string> Elements = new Dictionary<string, string>();
public int OrderID;
public List<Result> Results = new List<Result>();
public string OrderMessage
{
get
{
return GetOrderString();
}
set
{
SetOrderString(value);
}
}
private string GetOrderString()
{
// Anything missing should be added as an empty string.
string[] elementArray = { "FrameNumber", "Sequence#", "Specimen ID (Accession#)", "Instrument Specimen ID", "Universal Test ID", "Priority", "Order Date/Time", "Collection Date/Time", "Collection End Time", "Collection Volume", "Collector ID", "Action Code", "Danger Code", "Relevant Clinical Info", "Date/Time Specimen Received", "Specimen Descriptor", "Ordering Physician", "Physician's Telephone Number", "User Field No.1", "User Field No.2", "Lab Field No.1", "Lab Field No.2", "Date/Time results reported or last modified", "Instrument Charge to Computer System", "Instrument Section ID", "Report Types", "Reserved Field", "Location or ward of Specimen Collection", "Nosocomial Infection Flag", "Specimen Service", "Specimen Institution" };
foreach (var item in elementArray)
{
if (!Elements.ContainsKey(item))
{
Elements.Add(item, "");
}
}
string output = Constants.STX + Elements["FrameNumber"].Trim('O') + "O|";
// Concatenate the Dictionary values and return the string.
output += Elements["Sequence#"] + "|";
output += Elements["Specimen ID (Accession#)"] + "|";
output += Elements["Instrument Specimen ID"] + "|";
output += Elements["Universal Test ID"] + "|";
output += Elements["Priority"] + "|";
output += Elements["Order Date/Time"] + "|";
output += Elements["Collection Date/Time"] + "|";
output += Elements["Collection End Time"] + "|";
output += Elements["Collection Volume"] + "|";
output += Elements["Collector ID"] + "|";
output += Elements["Action Code"] + "|";
output += Elements["Danger Code"] + "|";
output += Elements["Relevant Clinical Info"] + "|";
output += Elements["Date/Time Specimen Received"] + "|";
output += Elements["Specimen Descriptor"] + "|";
output += Elements["Ordering Physician"] + "|";
output += Elements["Physician's Telephone Number"] + "|";
output += Elements["User Field No.1"] + "|";
output += Elements["User Field No.2"] + "|";
output += Elements["Lab Field No.1"] + "|";
output += Elements["Lab Field No.2"] + "|";
output += Elements["Date/Time results reported or last modified"] + "|";
output += Elements["Instrument Charge to Computer System"] + "|";
output += Elements["Instrument Section ID"] + "|";
output += Elements["Report Types"] + "|";
output += Elements["Reserved Field"] + "|";
output += Elements["Location or ward of Specimen Collection"] + "|";
output += Elements["Nosocomial Infection Flag"] + "|";
output += Elements["Specimen Service"] + "|";
output += Elements["Specimen Institution"] + Constants.CR + Constants.ETX;
return output;
}
private void SetOrderString(string input)
{
string[] inArray = input.Split('|');
if (inArray.Length < 31)
{
// Invalid number of elements.
throw new Exception("Invalid number of elements in order record string.");
}
Elements["FrameNumber"] = inArray[0];
Elements["Sequence#"] = inArray[1];
Elements["Specimen ID (Accession#)"] = inArray[2];
Elements["Instrument Specimen ID"] = inArray[3];
Elements["Universal Test ID"] = inArray[4];
Elements["Priority"] = inArray[5];
Elements["Order Date/Time"] = inArray[6];
Elements["Collection Date/Time"] = inArray[7];
Elements["Collection End Time"] = inArray[8];
Elements["Collection Volume"] = inArray[9];
Elements["Collector ID"] = inArray[10];
Elements["Action Code"] = inArray[11];
Elements["Danger Code"] = inArray[12];
Elements["Relevant Clinical Info"] = inArray[13];
Elements["Date/Time Specimen Received"] = inArray[14];
Elements["Specimen Descriptor"] = inArray[15];
Elements["Ordering Physician"] = inArray[16];
Elements["Physician's Telephone Number"] = inArray[17];
Elements["User Field No.1"] = inArray[18];
Elements["User Field No.2"] = inArray[19];
Elements["Lab Field No.1"] = inArray[20];
Elements["Lab Field No.2"] = inArray[21];
Elements["Date/Time results reported or last modified"] = inArray[22];
Elements["Instrument Charge to Computer System"] = inArray[23];
Elements["Instrument Section ID"] = inArray[24];
Elements["Report Types"] = inArray[25];
Elements["Reserved Field"] = inArray[26];
Elements["Location or ward of Specimen Collection"] = inArray[27];
Elements["Nosocomial Infection Flag"] = inArray[28];
Elements["Specimen Service"] = inArray[29];
Elements["Specimen Institution"] = inArray[30];
}
public Order(string orderMessage)
{
SetOrderString(orderMessage);
}
public Order(string orderMessage, int orderID)
{
SetOrderString(orderMessage);
OrderID = orderID;
}
public Order()
{
SetOrderString("O||||||||||||||||||||||||||||||");
}
}
}