RJ45 dianostic port pinout

Pin
2 SCL
3 GND
4 GND
5 +15V
7 SDA

The SCL, SDA are I2C lines with a 5V pull-up (5,6K) connecting straight to the CPU on the Itho mainboard.

+15V can be used for power supply needs (appears to be good for at least 1A).

There is no +5V available, but is not needed due to the built-in pull-ups (the lines only need to be pulled down for a logical 0).


GPIO Pin assignment

GPIO Desc Notes
0 Reset The ESP32 reset pin (inverted)
13 I2C Sniffer SDA Defined in i2c_sniffer.h
14 I2C Slave SDA Defined in i2c_slave.h
15 DHT22 I/O Defined in dht.h
25 I2C Sniffer SCL
26 I2C Master SCL Defined in i2c_master.h
27 I2C Master SDA
33 I2C Slave SCL

The I2C pins were carefully chosen so that they can be wired into a "bus", as can be seen on the schematic:

schematic


I2C message format

The Itho mainboard is an I2C master running at ~100kHz.
Each packet has a checksum byte at the end, which is the negative sum of all other bytes.
First byte is destination address (0x82 = Itho mainboard).
Second byte is reply address (0x80 = dongle).
2 bytes: message code.
1 byte: message flags (it seems: 06 = write, 04 = request, 01 = reply).
1 byte: payload length (N).
N bytes: payload.
1 byte: checksum.


Message 90 E0: query device type

82 80 90 E0 04 00 8A

Example reply:

80 82 90 E0 01 12 00 01 00 03 12 0B 00 00 00 FF FF FF FF FF FF FF FF 00 62

00 = Manufacturer (Itho), 03 = Device type (HRU), 12 = HW version, 0B = list version.

The "list version" refers to the Datalabel_V.. table in the corresponding Jet DB (.par) file of the Servicetool.

Some known Device Type codes:

01 : Lucht gordijn
03 : HRU ECO-fan
08 : Laadboiler
0A : Gas gestookte boost boiler
0B : DemandFlow
0C : CO2 relay
0D : Warmtepomp
0E : Oplaadboiler enkele wisselaar
0F : AutoTemp
10 : Oplaadboiler dubbele wisselaar
11 : RF+
14 : CVE
15 : Extended
16 : Extended Plus
1A : AreaFlow
1B : CVE-Silent
1C : CVE-SilentExt
1D : CVE-SilentExtPlus
20 : RF_CO2
2B : HRU 350


Message 90 E1: query device serial number

82 80 90 E1 04 00 89

Example reply (edited):

80 82 90 E1 01 03 52 D3 3C 48

Serial nr: 52D33C = 5428028


Message A4 00: query status format

82 80 A4 00 04 00 56

Example reply:

80 82 A4 00 01 16 91 11 10 90 10 90 92 92 00 92 92 00 00 91 00 10 10 00 90 00 00 10 C8

A4 00 01 followed by number of data elements, followed by element formats (1 byte per element).

Data format (1 byte):

Bit Description
7 signed (1) / unsigned (0)
6..4 size in bytes (2^n): 0=1, 1=2, 2=4
3..0 decimal digits (divider 10^n)

So for example 91 would mean "signed, 2 bytes, 0.1 values".

Special cases:

0C: unsigned 1 byte
0F: unsigned 1 byte * 0.5
5B: unsigned 2 bytes
6C: 1 byte boolean


Message A4 01: query device status

82 80 A4 01 04 00 55

Example reply:

80 82 A4 01 01 25 00 00 03 9C 03 9E 03 98 03 EB 03 EB 09 09 09 8A 00 09 09 09 8A 00 00 0B B8 01 00 00 00 B1 79 00 00 00 00 10 95 9F

80 82 A4 01 01 followed by data size and data formatted according to the status format (see previous message).

The temperatures are the bytes 09 09 09 8A, or (0x0909 and 0x098A) 23.13 C en 24.42 C respectively (.01 values).

The first 00 00 is the ventilation level. It goes from 0 for position "1" to 03E8 (100.0) for level "3".

For the meaning of each data element refer to Itho Data Labels.xlsx


Itho ecofan RFT 536-0124 (RF remote control) messages

Button 1:
82 60 C1 01 01 11 (4b: msg timestamp) (1b: msg format) (3b: commander ID) (1b: command seq nr) 22 F1 03 00 02 04 (2b: seq) (1b: checksum)

Button 2:
82 60 C1 01 01 11 (4b: msg timestamp) (1b: msg format) (3b: commander ID) (1b: command seq nr) 22 F1 03 00 03 04 (2b: seq) (1b: checksum)

Button 3:
82 60 C1 01 01 11 (4b: msg timestamp) (1b: msg format) (3b: commander ID) (1b: command seq nr) 22 F1 03 00 04 04 (2b: seq) (1b: checksum)

Button 4 (1st press):
82 60 C1 01 01 11 (4b: msg timestamp) (1b: msg format) (3b: commander ID) (1b: command seq nr) 22 F3 03 00 00 0A (2b: seq) (1b: checksum)

Button 4 (2nd press):
82 60 C1 01 01 11 (4b: msg timestamp) (1b: msg format) (3b: commander ID) (1b: command seq nr) 22 F3 03 00 00 14 (2b: seq) (1b: checksum)

Button 4 (3rd press):
82 60 C1 01 01 11 (4b: msg timestamp) (1b: msg format) (3b: commander ID) (1b: command seq nr) 22 F3 03 00 00 1E (2b: seq) (1b: checksum)

Register an RFT (press 1+4 or 2+3):
82 60 C1 01 01 1A (4b: msg timestamp) (1b: msg format) (3b: commander ID) (1b: command seq nr) 1F C9 0C 00 22 F1 (3b: commander ID) 01 10 E0 (3b: commander ID) (2b: seq) (1b: checksum)

Deregister an RFT (press 1+2+3+4):
82 60 C1 01 01 14 (4b: msg timestamp) (1b: msg format) (3b: commander ID) (1b: command seq nr) 1F C9 06 00 1F C9 (3b: commander ID) (2b: seq) (1b: checksum)

Notes:

  • Each command is repeated 3 times with a short interval
  • Note sure if my interpretation of (4b: msg timestamp), (1b: command seq nr), (2b: seq) is correct, most can be 00's but some itho devices (but not the HRU) need to have the command seq nr changed every message.
  • (3b: commander ID) are the 3 bytes of the device ID
  • (1b: msg format) is the message format determining the fields present in the message. For standard 4 button remotes this is 16.

...