'0x00158d000192dd3e': friendly_name: living heat retain: true
-
'living heat' (Eurotronic) failing device
- 0x00158d000192dd3e / 00:15:8d:00:01:92:dd:3e
- 0x21f3 = 8691
-
coordinator : 'power lifo'
- 0x00124b001d4a014b / 00:12:4b:00:1d:4a:01:4b
- 0x0000
-
router : 'power router'
- 0x00124b001c2f1279 / 00:12:4b:00:1c:2f:12:79
- 0xd5b1 = 54705
-
bathroom heat (Eurotronic) properly running device
- 0x82f2= 33522
-
bedroom heat
- 0x00158d0001922d4f
- 0x82f7 = 33527
2020-06-28 14:50:01
error 2020-06-28 14:50:01: Publish 'set' 'current_heating_setpoint' to 'living heat' failed: 'Error: Write 0x00158d000192dd3e/1 hvacThermostat({"16387":{"value":1100,"type":41}}, {"timeout":10000,"disableResponse":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":4151,"transactionSequenceNumber":null}) failed (Error: Data request failed with error: 'MAC transaction expired' (240))'
debug 2020-06-28 14:50:01: Error: Write 0x00158d000192dd3e/1 hvacThermostat({"16387":{"value":1100,"type":41}}, {"timeout":10000,"disableResponse":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":4151,"transactionSequenceNumber":null}) failed (Error: Data request failed with error: 'MAC transaction expired' (240))
at Endpoint.<anonymous> (/opt/zigbee2mqtt/node_modules/zigbee-herdsman/dist/controller/model/endpoint.js:162:23)
at Generator.throw (<anonymous>)
at rejected (/opt/zigbee2mqtt/node_modules/zigbee-herdsman/dist/controller/model/endpoint.js:6:65)
- time : 16:21:13
- 2567 16:21:13.398690 0.008497 ZCL: Write Attributes, Seq: 33 00:12:4b:00:1d:4a:01:4b 0x0000 0x21f3 -64dBm 116 ZigBee HA 65 0xb0f4 81 ✓
- 2569 16:21:13.404913 0.005676 ZCL: Write Attributes Response, Seq: 33 00:15:8d:00:01:92:dd:3e 0x21f3 0x0000 -83dBm 44 ZigBee HA 71 0xb0f4 77 ✓
-
bedroom write success / feedback success :
- <- DataRequest (17:05:25.426790)
- -> WriteAttribute (17:05:25.437033)
- <- WriteAttributeResponse (17:05:25.442254)
- <- ReportAttributes (17:05:26.408171)
-
living heat write success but feedback fail :
- <- DataRequest (17:08:30.778181)
- -> WriteAttribute (17:08:30.788673)
- <- WriteAttributesResponse (17:08:30.795426)
- Lost of DataRequest but no ReportAttribute