-
-
Notifications
You must be signed in to change notification settings - Fork 17
Alarms
Timely alarms should be looked at (they are alarms of course), but as their name implies are not as urgent as the others.
-
Reactor Lost
: In isolation this generally isn't a big deal (probably a timeout, or something got turned off), but it could be bad, so it's up to operator discretion. If the reactor was at high damage, thenContainment Breach
will be tripped as well, which is aCRITICAL
alarm. -
Reactor High Temp
: Reactor temperature at or exceeded 1150K. -
RPS Transient
: An RPS trip has occurred that was not due to manual operator SCRAM or a timeout. -
RCS Transient
: RCS transient conditions have been met (see below).
An RCS transient is caused by any of the following per the Annunciator
- Reactor coolant level low
- Boiler water level low
- Turbine over speed
- Reactor coolant related RPS trip (coolant low, excess heated coolant)
- RCS flow low
- Max water return feed
- If "flow stability delay" has elapsed (15 seconds since last burn rate change), then
- Boil rate mismatch
- Coolant feed mismatch
- Steam feed mismatch
Urgent alarms demand operator attention, but are not immediate threats unless ignored.
-
Reactor Over Temp
: Reactor is over-temperature (≥1200K) and is now starting to take damage, but will not meltdown until ≥100% damage. A timer will be shown on the status to estimate how much time until 100% damage is reached. -
Reactor High Waste
: Reactor waste has exceeded 85% full. At 100%, excess waste will vent and release significant amounts of radiation.
Emergency alarms represent a safety threat and may warrant evacuation after a facility SCRAM due to threat of a meltdown and/or radiation leaks.
-
Reactor Damage
: The reactor containment is taking damage, and a meltdown will occur at some point at or after 100% damage. -
Reactor Waste Leak
: The reactor waste tank is full and radiation is now leaking.
Remaining in the facility (if near the reactors) is very much not recommended at this point. Evacuation is encouraged.
-
Containment Breach
: The reactor melted down (guessed by reactor not being formed, not being connected, and having previously been >90% damage). -
Containment Radiation
: Radiation has been detected at the unit radiation monitor (if configured). -
Critical Damage
: The reactor has met or exceeded critical levels of damage and may meltdown at any point.
The orange button can be used to acknowledge (mute) individual alarms. The green button will Reset alarms in the "ring-back" state (alarm condition has been resolved). A green light indicates the alarm is in the ring-back state, meaning that the triggering conditions are no longer met, but the alarm had tripped since last reset. This allows the operator to know if something had happened that they missed.
The cyan tag next to the RPS transient indicates it is tied RPS data (which is in the cyan-bordered annunciator panel).
The blue tag next to RCS transient and turbine trip indicates those are tied to RCS data (which is in the blue-bordered annunciator panel).
-
Containment Breach
→ red @ 4Hz light -
Containment Radiation
→ red @ 4Hz light -
Critical Damage
→ red @ 4Hz light -
Reactor Lost
→ red @ 4Hz light -
Reactor Damage
→ red @ 4Hz light -
Reactor Over Temp
→ red @ 4Hz light -
Reactor High Temp
→ yellow @ 2Hz light -
Reactor Waste Leak
→ red @ 4Hz light -
Reactor High Waste
→ yellow @ 2Hz light -
RPS Transient
→ yellow @ 2Hz light -
RCS High Waste
→ yellow @ 2Hz light -
Turbine Trip
→ red @ 4Hz light
A speaker is used to play auditory alarms to accompany the alarm lights. For the sake of everyone's ears, alarms do not stack up. Multiple different sine waves start sounding really bad if you add them all together, so that is minimized by only playing alarms in combination that sound okay together.
-
T_340Hz_Int_2Hz
→ 340Hz @ 2Hz Intermittent -
T_544Hz_440Hz_Alt
→ 544Hz 100mS / 440Hz 400mS Alternating -
T_660Hz_Int_125ms
→ 660Hz @ 125ms On 125ms Off -
T_745Hz_Int_1Hz
→ 745Hz @ 1Hz Intermittent -
T_800Hz_Int
→ 800Hz @ 0.25s On 1.75s Off -
T_800Hz_1000Hz_Alt
→ 800/1000Hz @ 0.25s Alternating -
T_1000Hz_Int
→ 1KHz 1s on, 1s off Intermittent -
T_1800Hz_Int_4Hz
→ 1.8KHz @ 4Hz Intermittent
-
Containment Breach
→ 1.8KHz @ 4Hz Intermittent -
Containment Radiation
→ 800/1000Hz @ 0.25s Alternating -
Critical Damage
→ 660Hz @ 125ms On 125ms Off -
Reactor Lost
→ 340Hz @ 2Hz Intermittent -
Reactor Damage
→ 544Hz 100mS / 440Hz 400mS Alternating -
Reactor Over Temp
→ 544Hz 100mS / 440Hz 400mS Alternating -
Reactor High Temp
→ 800Hz @ 0.25s On 1.75s Off -
Reactor Waste Leak
→ 544Hz 100mS / 440Hz 400mS Alternating -
Reactor High Waste
→ 800Hz @ 0.25s On 1.75s Off -
RPS Transient
→ 1KHz 1s on, 1s off Intermittent -
RCS High Waste
→ 800Hz @ 0.25s On 1.75s Off -
Turbine Trip
→ 745Hz @ 1Hz Intermittent
-
Containment Breach
takes priority and will play instead of any other alarms. - otherwise
Critical Damage
-
RPS Transient
(and disable T_340Hz_Int_2Hz) - if not critical damage:
-
Reactor Damage
orReactor Over Temp
orReactor Waste Leak
Turbine Trip
Reactor Lost
-
Reactor High Temp
orReactor High Waste
orRCS Transient
-
Containment Radiation
will always play in synchrony with any other alarms, including Containment Breach
. In order to avoid bad audio combinations:
- Disable
RPS Transient
alarm if active due to conflict - Re-enable
Reactor Lost
alarm due to no longer conflicting withRPS Transient
(if alarm is active) - Also disable T_745Hz_Int_1Hz, T_800Hz_Int, T_1000Hz_Int
If you need help beyond this wiki, open a support discussion or ask on Discord! If you prefer videos, they can be found on my YouTube channel.
- User Manual
- Computer Applications
- Notable System Components
- Notes
- Investigations
- References & Resources
- Legacy