3.6.0

23 Oct 12:51
Compare
Choose a tag to compare
  • add: Launchfiles and configuration for picoScan120
  • add: Optional AngleRangeFilter and IntervalFilter for picoScan
  • fix: Obsolete topic "/sick_multiscan/scan" removed
  • add: IMU automatically deactivated after receiving an error code for IMU activation from picoScan w/o addons
  • fix: Customization of hash values for authorization #366
  • fix: Replaced builtin_addressof expressions #370
  • add: Different UDP timeouts for state initial and running, improved UDP timeout handling
  • fix: Picoscan range_min value in laserScan message #382
  • add: Support for RMS2xxx LIDoutputstate telegrams
  • fix: sick_generic_caller debug assertion #385
  • add: Check of udp receiver ip at startup
  • add: cmake-option to overwrite optimization level
  • change: Documentation restructured
  • add: Improved field evaluation TiM7xx, Tim7xxS (publish LIDinputstate messages, configuration and services for options FieldSetSelectionMethod and ActiveFieldSet)
  • fix: PicoScan parameter add_transform_xyz_rpy #399
  • fix: LMS4000 encoder settings #403
  • fix: CMake-flag for target sick_scan_xd_api_dockertest #404
  • change: Merge PR #405 (typo) and PR #406 (sick_scan_xd_api_test)

3.5.0

19 Jul 10:20
Compare
Choose a tag to compare
  • add Optional switch between "system timestamps" (default) and "tick timestamps"
  • add Extract sick_scan_xd version from package.xml
  • add Add git info to sick_scan_xd version
  • fix #316 (blocking API-close in case of wrong ip-address)
  • add #321, #310 (optional cmake-flag to set a calling convention for API calls)
  • add Hector SLAM configuration and example for picoScan
  • add Correction angle shift settings for LRS-36x0 and OEM-15xx
  • add Update FAQ (Network settings etc.)
  • add Integration PR #347 (NAV350 landmarks)
  • add Support for 3D-SLAM (OctoMap, RTAB-Map, timestamps for each scanpoint for deskewing, configuration example for multiScan)
  • add customisations for gcc 13 (Ubuntu 24)
  • add Update for bloom releases ROS-2 iron and jazzy
  • add Configuration multiScan interval filter via launchfile (#352)
  • add SPDX licence text (PR #354)
  • fix Fix #355 (API launchfile parsing error)
  • add Example configurations for parallel operation multi and picoScan

Release 3.4.0

29 May 09:55
9fbf194
Compare
Choose a tag to compare
  • add azimuth angle table for MRS-1xxx and LMS-1xxx with firmware 2.2.0 oder newer
  • add docker tests for MRS-1xxx, multiScan and picoScan with ROS-2
  • add API-funktion SickScanApiSendSOPAS to send SOPAS commands (e.g. "sRN SCdevicestate" or "sRN ContaminationResult")
  • add generation of TF messages
  • add Option to deactivate initialization sequence for TiM-7xxS devices
  • add Documented option "-b master" to clone the release version
  • fix #316 API re-init nach close

Release v3.3.0

02 Apr 08:07
aebcc72
Compare
Choose a tag to compare
Release v3.3.0 Pre-release
Pre-release
  • add Option for MRS1xxx azimuth correction table
  • add Support for picoScan100 (single echo w/o addons)
  • add API logging functions and verbosity (#270)
  • add API documentation (multiple lidars not supported, #281)
  • changed API extended (added topic in PointCloud messages, #271)

Release v3.2.0

12 Feb 12:45
Compare
Choose a tag to compare
  • add IMU support for multiScan and picoScan
  • add support bloom releases for ROS-2 humble
  • add docker tests for ROS1 noetic incl. testcases for multiScan, picoScan, MRS1xxx
  • add PR #255, support picoScan performance profiles
  • changed configuration time flag LMDscandatacfg switched off for the TiM240
  • fix #218 (API reinit)
  • fix #220 (Fullframe Laserscan messages multi- and picoScan)
  • fix #221 (No scandata while activated scan range filter)
  • fix #222 (rviz visualization of polar pointclouds)
  • fix #247 (Launchfile option for laserscan topic)
  • fix #256 (Clean API-exit picoScan and multiScan)
  • fix #260 (Provide API-functions to query lidar status, error codes and error messages)

Release v3.1.0

21 Nov 09:34
Compare
Choose a tag to compare
  • add IMU support for multiScan
  • add LaserScan output for picoScan
  • fix API reinit
  • fix multiScan data output with range filter activated
  • fix adapt multiScan startup and shutdown sequence
  • fix adaptations for MRS-1000 v2 firmware

Release v3.0.0 - Rename ROS module to sick_scan_xd

11 Oct 09:39
Compare
Choose a tag to compare

This release has a new major version as it breaks with the previously used ROS module name "sick_scan".
For consistency, the ROS module name has been changed to "sick_scan_xd" to match the name used everywhere else.

  • add New topics for additional data and properties
  • add Official ARM64 support
  • add Service for requesting contamination detection information
  • changed Improvements from customer tickets and documentation enhancements
  • fix ROS module name consistency

Release v2.10.2 - picoScan and Compact format support

01 Sep 08:21
Compare
Choose a tag to compare
  • add picoScan support
  • add Compact format support
  • add LMS4000 encoder setting support
  • update make Compact format the default for picoScan and multiScan
  • fix multiScan angle range filter parameter unit
  • fix MRS1104 diagnostic message
  • fix TiM781S login
  • fix correct picoScan details in documentation and launch files

Release v2.9.1 - Angle correction

15 May 06:53
6825960
Compare
Choose a tag to compare
  • Angle correction (min/max angle settings), fix TIM551 points have bad coordinates. #166
  • TiM240 initialization (start measurement)

Release v2.9.0 - RMSxxxx support and NAV350 support

05 May 08:00
Compare
Choose a tag to compare
  • Added RMSxxxx support, unification of RMS-1xxx and RMS-2xxx Note: RMSxxxx supports ASCII-communication mode only (Cola-A).
  • Update #159 (nav310 angle setting compability), merge with NAV310 angle settings branch https://github.com/SICKAG/sick_scan_xd/tree/159-nav310-angle-setting-compability
  • Update Documentation LD-LRS3600,LD-LRS3601,LD-LRS3611,LD-OEM1500,LD-OEM1501 support
  • Update Removed obsolete RMS-3xx
  • Added NAV350 support
  • Update Merge lms511_field_mon (fix lms511 field parsing and wait api), default_echo_setting (activate last echo by default), monitoring_ros2_qos (ROS2 QoS configuration), scansegment_xd_support (update build instructions), rename-mrs100-multiscan, rename-fullframe-topic