Topic | Description |
---|---|
jurabridge/power | Last will message of "off" to indicate bridge is off (not machine) |
jurabridge/ready | Boolean for whether system is ready or not |
Topic | Description | Details |
---|---|---|
jurabridge/command | Post a custom automation or recipe formatted as an array of command arrays | Instructions |
jurabridge/menu | Run through the menu structure to perform a task within the menus (e.g., rinses) |
rinse ,mclean ,mrinse ,clean ,filter
|
Topic | Type | Direct, Calculated, Inferred | Description |
---|---|---|---|
jurabridge/counts/beans | Integer | Inferred (200g hopper volume - 8g/grind) | Approximate bean hopper percentage remaining |
jurabridge/counts/cappuccino | Integer | Direct | Lifetime counts of cappuccino preparations |
jurabridge/counts/cleans | Integer | Direct | Lifetime count of tablet clean operations |
jurabridge/counts/coffee | Integer | Direct | Lifetime count of coffee preparations |
jurabridge/counts/espresso | Integer | Direct | Lifetime count of espresso preparations |
jurabridge/counts/grinder | Integer | Direct | Lifetime count of grinder operations |
jurabridge/counts/grounds | Integer | Direct | Pucks in grounds hopper |
jurabridge/counts/high pressure operations | Integer | Direct | Lifetime count of high pressure pump cycles |
jurabridge/counts/hot water | Integer | Direct | Lifetime count of hot water preparations |
jurabridge/counts/low pressure operations | Integer | Direct | Lifetime count of low pressure pump cycles |
jurabridge/counts/macchiato | Integer | Direct | Lifetime count of macchiato preparations |
jurabridge/counts/milk clean | Integer | Direct | Lifetime count of m-clean operations |
jurabridge/counts/milk foam | Integer | Direct | Lifetime count of milk foam preparations |
jurabridge/counts/since clean | Integer | Direct | Preparations since last clean (clean recommended at 180) |
jurabridge/counts/total automations | Integer | Calculated | Lifetime count total preparations |
jurabridge/counts/tray volume | Integer | Inferred (drainage per preparation + low pressure operations) | Estimated ml in tray |
jurabridge/counts/water tank/volume | Integer | Inferred (1L tank - dispense volume) | Estimated fill percentage in reservoir |
Topic | Direct or Inferred | Description |
---|---|---|
jurabridge/errors/beans | Direct | Beans hopper lid removed |
jurabridge/errors/grounds | Direct | Grounds needs emptying |
jurabridge/errors/powder | Direct | Powder door / bypass doser is open |
jurabridge/errors/reservoir low | Inferred | Water fill required soon |
jurabridge/errors/tray overfill | Inferred | Tray likely needs emptying |
jurabridge/errors/tray removed | Direct | Tray is removed |
jurabridge/errors/water | Direct | Water fill required; replace reservoir |
Topic | Type | Description |
---|---|---|
jurabridge/history | String | Last automation/task completed |
Topic | Description |
---|---|
jurabridge/machine/brewgroup | Status position of brewgroup |
jurabridge/machine/custom execution | Currently executing a custom program |
jurabridge/machine/input board | Input board ready |
jurabridge/machine/input board/state | Input board state |
jurabridge/machine/last dispense | Volume of last dispense |
jurabridge/machine/last grind duration | Approximate duration of last grind operation |
Topic | Description |
---|---|
jurabridge/parts/ceramic valve/mode | Ceramic valve in steam or water mode / position |
jurabridge/parts/ceramic valve/position | Ceramic valve position |
jurabridge/parts/ceramic valve/temp | Ceramic valve temperature |
jurabridge/parts/grinder/active | Grinder is currently grinding |
jurabridge/parts/output valve/position | Output valve position |
jurabridge/parts/pump/active | Pump is pumping |
jurabridge/parts/pump/duty | Duty cycle of pump |
jurabridge/parts/pump/flowing | Flow sensor indicates flow in hydraulic system |
jurabridge/parts/pump/status | Status of pump |
jurabridge/parts/thermoblock/active | Thermoblock is actively heating |
jurabridge/parts/thermoblock/duty | Duty cycle of thermoblock (nearly always 100%) |
jurabridge/parts/thermoblock/preheated | Thermoblock is preheated |
jurabridge/parts/thermoblock/temp | Temperature of thermoblock |
Topic | Description |
---|---|
jurabridge/recommendation | Current highest priority recommendation |
jurabridge/recommendations/milk clean | Whether m-clean is recommended |
jurabridge/recommendations/milk rinse | Whether m-rinse is reecommended |
jurabridge/recommendations/rinse | Whether water rinse is recommended |
jurabridge/system | Narrative description of system status |