The input data is located in the data directory, as the mat-file with the struct variable data
. The state estimation module, except the measurement data, requires quantities that describe the physical structure of the power system which are located in variable data.system
. Measurement data are given in variables data.legacy
and data.pmu
, with variables flow, current, injection, voltage for legacy measurements, and current, voltage for phasor measurement units (PMUs).
The minimum amount of information with each instance of the data structure to run the module requires one of the types of measurements (e.g., data.legacy.flow
).
Power flow measurement data are located in data.legacy.flow
with the structure:
Column | Description | Unit |
---|---|---|
1 | from bus number | |
2 | to bus number | |
3 | active power flow measurement | per-unit |
4 | active power flow variance | per-unit |
5 | on/off status | |
6 | reactive power flow measurement | per-unit |
7 | reactive power flow variance | per-unit |
8 | on/off status | |
9 | active power flow exact value (optional) | per-unit |
10 | reactive power flow exact value (optional) | per-unit |
Line current magnitude measurement data are located in data.legacy.current
with the structure:
Column | Description | Unit |
---|---|---|
1 | from bus number | |
2 | to bus number | |
3 | line current magnitude measurement | per-unit |
4 | line current magnitude variance | per-unit |
5 | on/off status | |
6 | line current magnitude exact value (optional) | per-unit |
Power injection measurement data are located in data.legacy.injection
with the structure:
Column | Description | Unit |
---|---|---|
1 | bus number | |
2 | active power injection measurement | per-unit |
3 | active power injection variance | per-unit |
4 | on/off status | |
5 | reactive power injection measurement | per-unit |
6 | reactive power injection variance | per-unit |
7 | on/off status | |
8 | active power injection exact value (optional) | per-unit |
9 | reactive power injection exact value (optional) | per-unit |
Bus voltage magnitude measurement data are located in data.legacy.voltage
with the structure:
Column | Description | Unit |
---|---|---|
1 | bus number | |
2 | bus voltage magnitude measurement | per-unit |
3 | bus voltage magnitude variance | per-unit |
4 | on/off status | |
6 | bus voltage magnitude exact value (optional) | per-unit |
Line current phasor measurement data are located in data.pmu.current
with the structure:
Column | Description | Unit |
---|---|---|
1 | from bus number | |
2 | to bus number | |
3 | line current magnitude measurement | per-unit |
4 | line current magnitude variance | per-unit |
5 | on/off status | |
6 | line current angle measurement | radian |
7 | line current angle variance | radian |
8 | on/off status | |
9 | line current magnitude exact value (optional) | per-unit |
10 | line current angle exact value (optional) | radian |
Bus voltage phasor measurement data are located in data.pmu.voltage
with the structure:
Column | Description | Unit |
---|---|---|
1 | bus number | |
2 | bus voltage magnitude measurement | per-unit |
3 | bus voltage magnitude variance | per-unit |
4 | on/off status | |
5 | bus voltage angle measurement | radian |
6 | bus voltage angle variance | radian |
7 | on/off status | |
8 | bus voltage magnitude exact value (optional) | per-unit |
9 | bus voltage angle exact value (optional) | radian |