Skip to content

Python reader of LabVIEW RSRC files (VI, CTL, LLB). File format description on the Wiki.

License

Notifications You must be signed in to change notification settings

mefistotelis/pylabview

 
 

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

pylabview

Tools for extracting, changing, and re-creating LabVIEV RSRC files, like VIs or CTLs.

Motivation

LabView environment is unneccessarily closed. Its mechanisms prevent the developers from modifying projects outside of the GUI, which makes scalability painful.

If you want to modify something in 1000 of files, and you're not really into clicking through all that, this might be the tool for you.

Besides batch processing of LabView files, this tool should be also helpful for fixing the ones which LabView refuses to read.

Tools

Running the tools without parameters will give you details on supported commands in each of them.

To get specifics about command line arguments of each tool, run them with --help option. Some tools also have additional remarks in their headers - try viewing them.

The first tool to use is readRSRC.py and extract the RSRC file into a form which is easier to understand and modify.

Supported versions

The tools were tested on all standard VIs from LabVIEW 2014 and LabVIEW 6.0. These standard VIs included a variety of versions, ie LV14 contains some VIs created in previous versions down to LabVIEW 8.6.

But the actual development was made with LabVIEW 2014 in mind. Other versions may get less resources converted to XML, or may require some tweaks to work.

Python environment

As for Python versions best suited to run these scripts - newer should be better. It is recommended to use at least Python 3.8, as XML parser is older versions does not preserve order of attributes. Without this feature the tool will still work (down to 3.5), but generated binary data will be different due to reordering of some tags. It is uncertain whether the different ordering has impact on stability of the created binary files. Some fixes to the XML parser from Python 3.9 can also affect generated files, due to better handling of non-text ASCII codes within values of attributes.

Running

To run the tools with your Python, use a shell like bash or cmd. You can have the scripts directly in the CWD, or installed as a module. If you choose the direct CWD option, remember you need to have pylabview folder in the CWD for Python to find the accompanying files.

Example command:

./pylabview/readRSRC.py --version

Verification

If you want to verify whether your specific file will be handled correctly by the tool, try:

  • extracting it to XML
  • re-creating it from the XML
  • checking whether oroginal and re-created file are binary identical, or load with all features in LabVIEW

Note that some files created by the tool will not be binary identical to the originals. This includes many LLB files, and some VIs from LV6.0 and older. The differenes in LLB can happen because string names in these files are not ordered, and the order depends on specific timing between threads while the file was saved (this tool always uses the same ordering of all items). The differenes in old VI files are due to unpredicatable values used for padding between actual data (this tool uses zeros for padding).

A few example files are included in the project.

Tests

The tool comes with a few tests, implemented to be used by pytest. To execute these, just run in home folder of the project:

pytest tests -o log_cli=true

These are the tests executed after each commit, providing Continous Integration for the project. Though there, additinal set of VI/LLB files is downloaded; you can fetch those files manually (the link is within .github/workflows scripts) and unzip them to the ./examples folder. All files within that folder are used during pytest runs.

The output files will be stored in test_out directory.

There is also a second set of tests, implementing similar test cases as shell scripts. Run them from bash:

cd tests
./recreate-vi_lib-llb.sh ../examples
./recreate-vi_lib-vis.sh ../examples

The output files and logs will be stored in test_out directory.

Use cases

The general intended use of the tools is as follows:

  • extract RSRC file to XML form
  • look at the resulting XML, perform modifications
  • re-create RSRC file from the XML

Several specific things you can do with these tools are listed below. One caveat worth noticing is that these tasks are not fully automated. To use these functions, you must know what you're doing, and modify the scripts where apropriate.

Look at the data inside VI file

If you don't have a LabVIEW license, and want to look inside some VIs, these tools can help. You can convert your VIs to XML format, and then look at the XML.

It is possible to write a viewer, which displays the XML data in graphical form, like they look in LabVIEW. Such viewer does not exist at the moment.

Look at the compiled code inside VI file

If you want to look at assembly bytecode, the tool will create a BIN file with that code during VI extraction. It will even prepare a MAP file, with some known symbols within the code. Base address of the extracted code is always 0x0. Relocations and imports are stored in an array called 'Patches', and for most versions of LV, the tool will store these within XML file.

Batch process VIs

You can extract, modify and re-create VIs. So as long as you can write a script which does proper modification to XMLs, you can automatically apply a change to thousands of VI files, without the need of clicking through LabVIEW GUI.

Reverse a compiled VI project

You can look into internals of a compiled VI project. You can also, to some extent, convert the EXE cack to source form. Though at the moment, the tools will not allow you to automatically recover Block Diagram which is lost during VIs compilation process. There is a script which recovers Front Panel from a VI which had it removed.

It is possible to write a tool which recovers these items completely, though.

Fix damaged VI files

The extractor can be modified to ignore errors and read damaged VI file. Then it can re-create the VI from XML, and it will use proper format required by LabVIEW. So it can be used to fix a VI file, though there is no premade parameter which will do it for you.

Backport VI files

You can modify version numbers in XML files, and the tools will re-create VIs using structures from the updated version markings. There is no automated version changer though - if the switch requires some blocks to be renamed, or some data added - you will have to do it manually.

Reversing EXE back to buildable project

While it is possible to reverse the EXE built with LabVIEW to its source, there are no tools to automate such conversion at the moment. When VI files are being build, some elements are removed from them:

  • Block Diagram is removed, leaving only compiled version. The compiled version is kind of OBJ file, which can only run on a specific CPU, and specific version of LabVIEW Runtime Environment (LVRT).
  • If GUI of the VI file is never shown, the unused VI Front Panel is also removed.

The missing elements can be re-created, and doing so with use of the XML format is much easier than doing that directly with binary form of the VI files. A script which reads the XML and re-constructs missing parts is in the project, though it currently reconstructs only Front Panel. The reconstructing script is not as thoroughly tested as the XML extractor, so may require some tweaks to work with a specific project.

Even without the VIs fully reversed so source form, it is possible to extract the EXE back to a project, which then can be re-built with the same version of LabView which was originally used. It is then possible to start replacing single VIs with a newly created ones, while retaining useability of the whole project.

In order to reverse an executable back to LabView project:

1. Extract RSRC file from the executable

Use any tool you see fit. In case of Windows PE executable, you may use wrestool, or if you prefer GUIs, Resource Hacker. You may also just find RSRC in file content and copy the data starting from that position, using dd. Any method should work, as long as you receive the file with RSRC header.

2. Decrypt the ZIP from within RSRC file

The RSRC file will contain weakly encrypted ZIP. Extract it with the tools from this repo.

3. Get proper LabVIEW version

Look inside VI files from the ZIP to figure out which version of LabVIEW was used to create them. You can look at the versions by extraction one of the vIs to XML form. Use the exact same version for further steps.

4. Make new LabView project

Create a folder. Open LabVIEW. Create new LabView project in the new folder.

5. Copy VIs to the project folder

Create sub-folder within the project folder, ie. app or lv or however you want to call the labview app part; copy the files extracted from ZIP there.

6. Copy non-VI dependencies

Copy any config and data files (and folders) distributed with original binary (either within the ZIP, or just placed in the same folder where the EXE you've extracted) to the project folder.

7. Copy LV Runtime Engine settings

Copy options from BinryName.ini into your BinaryName.lvproj (created in step 4).

8. Open the project in LabView

Just run LabVIEW and open your project. Noe that LabVIEW still considers your project to be empty.

9. Add VIs to the LV project

Add each folder from your labview app part to the project. Use "My Computer" -> "Add" -> "Folder (Auto-populating)".

10. Create build target in the LV project

To make the new build target, use "Build Specifications" -> "New" -> "Application".

11. Set build target settings

Set proper "Name: and "Target filename" in build target "Information" tab.

12. Set build target Startup VI

Look at the starting form from original app. Find the starting panel in your VIs, and add it as "Startup VIs" in build target "Source files" tab.

You shouldn't have to put anything in "Always included" list in build target "Source files" tab. Each VI stores its dependencies, so LV should be able to figure out which files to include in your build. But if you want - you can add some files there now.

13. Disable removing things from VIs

Disable all the "Remove ..." and "Disconnect ..." options in build target "Additional Exclusions" tab.

14. Fix "Missing items"

LabVIEW will likely inform you of "Missing items" in the project. You can fix these by placing files in correct places or modifying file paths within the files which reference them. Usually, LabVIEW will ask you dozens of questions in regard to which file you want to use; but after that, most "Missing items" will be fixed. Probably not all though - VIs with both Front Panel and Block Diagram removed will require manual fixing of the paths inside, as LabVIEW will refuse to load them, and therefore will not re-save them with different paths.

15. Build the project

If you encounter further errors, fix them. If you've solved the "Missing items", everything else is simple and you shouldn't have much problems.

Now you have a LabVIEW project which allows you to re-build the EXE.

You may look into converting to XML all the VIs which are missing Front Panel, and recovering these Front Panels.

Text Code Pages

The RSRC files use various code pages, depending on OS on which the file was created. On reading RSRC file, you can provide the code page as a parameter.

Example code pages you could use:

TextEncoding Related Operating System
mac_cyrillic MacOS Bulgarian, Byelorussian, Macedonian, Russian, Serbian
mac_greek MacOS Greek
mac_iceland MacOS Icelandic
mac_latin2 MacOS Central and Eastern Europe
mac_roman MacOS Western Europe (and US)
mac_turkish MacOS Turkish
cp1250 Windows Central and Eastern Europe
cp1251 Windows Bulgarian, Byelorussian, Macedonian, Russian, Serbian
cp1252 Windows Western Europe (and US)
cp1253 Windows Greek
cp1254 Windows Turkish
cp1255 Windows Hebrew
cp1256 Windows Arabic
cp1257 Windows Baltic languages
cp1258 Windows Vietnamese
shift_jis Windows Japanese
gbk Windows Chinese (simplified)
cp949 Windows Korean Hangul
cp950 Windows Chinese (traditional)
utf-8 Universal encoding, used by everyone except NI for decades

Note that changing text code pages of VI files will not influence extraction of ZIP files which were stored inside RSRC sections, and the code pages of file names within the ZIP. Use proper unzip switches to change these.

File format

To learn about file format, check out wiki of this project.

About

Python reader of LabVIEW RSRC files (VI, CTL, LLB). File format description on the Wiki.

Topics

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages

  • Python 99.4%
  • Shell 0.6%