Skip to content

Commit

Permalink
gh-116750: Add clear_tool_id function to unregister events and callba…
Browse files Browse the repository at this point in the history
…cks (#124568)
  • Loading branch information
gaogaotiantian authored Oct 1, 2024
1 parent b482538 commit 5e0abb4
Show file tree
Hide file tree
Showing 8 changed files with 165 additions and 8 deletions.
12 changes: 5 additions & 7 deletions Doc/library/sys.monitoring.rst
Original file line number Diff line number Diff line change
Expand Up @@ -50,16 +50,14 @@ Registering and using tools
*tool_id* must be in the range 0 to 5 inclusive.
Raises a :exc:`ValueError` if *tool_id* is in use.

.. function:: free_tool_id(tool_id: int, /) -> None
.. function:: clear_tool_id(tool_id: int, /) -> None

Should be called once a tool no longer requires *tool_id*.
Unregister all events and callback functions associated with *tool_id*.

.. note::
.. function:: free_tool_id(tool_id: int, /) -> None

:func:`free_tool_id` will not disable global or local events associated
with *tool_id*, nor will it unregister any callback functions. This
function is only intended to be used to notify the VM that the
particular *tool_id* is no longer in use.
Should be called once a tool no longer requires *tool_id*.
Will call :func:`clear_tool_id` before releasing *tool_id*.

.. function:: get_tool(tool_id: int, /) -> str | None

Expand Down
4 changes: 4 additions & 0 deletions Include/cpython/code.h
Original file line number Diff line number Diff line change
Expand Up @@ -8,6 +8,8 @@
extern "C" {
#endif

/* Total tool ids available */
#define _PY_MONITORING_TOOL_IDS 8
/* Count of all local monitoring events */
#define _PY_MONITORING_LOCAL_EVENTS 10
/* Count of all "real" monitoring events (not derived from other events) */
Expand Down Expand Up @@ -57,6 +59,8 @@ typedef struct {
_Py_LocalMonitors active_monitors;
/* The tools that are to be notified for events for the matching code unit */
uint8_t *tools;
/* The version of tools when they instrument the code */
uintptr_t tool_versions[_PY_MONITORING_TOOL_IDS];
/* Information to support line events */
_PyCoLineInstrumentationData *lines;
/* The tools that are to be notified for line events for the matching code unit */
Expand Down
1 change: 1 addition & 0 deletions Include/internal/pycore_interp.h
Original file line number Diff line number Diff line change
Expand Up @@ -272,6 +272,7 @@ struct _is {
Py_ssize_t sys_tracing_threads; /* Count of threads with c_tracefunc set */
PyObject *monitoring_callables[PY_MONITORING_TOOL_IDS][_PY_MONITORING_EVENTS];
PyObject *monitoring_tool_names[PY_MONITORING_TOOL_IDS];
uintptr_t monitoring_tool_versions[PY_MONITORING_TOOL_IDS];

struct _Py_interp_cached_objects cached_objects;
struct _Py_interp_static_objects static_objects;
Expand Down
41 changes: 41 additions & 0 deletions Lib/test/test_monitoring.py
Original file line number Diff line number Diff line change
Expand Up @@ -46,10 +46,14 @@ def nth_line(func, offset):

class MonitoringBasicTest(unittest.TestCase):

def tearDown(self):
sys.monitoring.free_tool_id(TEST_TOOL)

def test_has_objects(self):
m = sys.monitoring
m.events
m.use_tool_id
m.clear_tool_id
m.free_tool_id
m.get_tool
m.get_events
Expand Down Expand Up @@ -77,6 +81,43 @@ def test_tool(self):
with self.assertRaises(ValueError):
sys.monitoring.set_events(TEST_TOOL, sys.monitoring.events.CALL)

def test_clear(self):
events = []
sys.monitoring.use_tool_id(TEST_TOOL, "MonitoringTest.Tool")
sys.monitoring.register_callback(TEST_TOOL, E.PY_START, lambda *args: events.append(args))
sys.monitoring.register_callback(TEST_TOOL, E.LINE, lambda *args: events.append(args))
def f():
a = 1
sys.monitoring.set_local_events(TEST_TOOL, f.__code__, E.LINE)
sys.monitoring.set_events(TEST_TOOL, E.PY_START)

f()
sys.monitoring.clear_tool_id(TEST_TOOL)
f()

# the first f() should trigger a PY_START and a LINE event
# the second f() after clear_tool_id should not trigger any event
# the callback function should be cleared as well
self.assertEqual(len(events), 2)
callback = sys.monitoring.register_callback(TEST_TOOL, E.LINE, None)
self.assertIs(callback, None)

sys.monitoring.free_tool_id(TEST_TOOL)

events = []
sys.monitoring.use_tool_id(TEST_TOOL, "MonitoringTest.Tool")
sys.monitoring.register_callback(TEST_TOOL, E.LINE, lambda *args: events.append(args))
sys.monitoring.set_local_events(TEST_TOOL, f.__code__, E.LINE)
f()
sys.monitoring.free_tool_id(TEST_TOOL)
sys.monitoring.use_tool_id(TEST_TOOL, "MonitoringTest.Tool")
f()
# the first f() should trigger a LINE event, and even if we use the
# tool id immediately after freeing it, the second f() should not
# trigger any event
self.assertEqual(len(events), 1)
sys.monitoring.free_tool_id(TEST_TOOL)


class MonitoringTestBase:

Expand Down
Original file line number Diff line number Diff line change
@@ -0,0 +1 @@
Provide :func:`sys.monitoring.clear_tool_id` to unregister all events and callbacks set by the tool.
29 changes: 28 additions & 1 deletion Python/clinic/instrumentation.c.h

Some generated files are not rendered by default. Learn more about how customized files appear on GitHub.

84 changes: 84 additions & 0 deletions Python/instrumentation.c
Original file line number Diff line number Diff line change
Expand Up @@ -1660,6 +1660,16 @@ update_instrumentation_data(PyCodeObject *code, PyInterpreterState *interp)
if (allocate_instrumentation_data(code)) {
return -1;
}
// If the local monitors are out of date, clear them up
_Py_LocalMonitors *local_monitors = &code->_co_monitoring->local_monitors;
for (int i = 0; i < PY_MONITORING_TOOL_IDS; i++) {
if (code->_co_monitoring->tool_versions[i] != interp->monitoring_tool_versions[i]) {
for (int j = 0; j < _PY_MONITORING_LOCAL_EVENTS; j++) {
local_monitors->tools[j] &= ~(1 << i);
}
}
}

_Py_LocalMonitors all_events = local_union(
interp->monitors,
code->_co_monitoring->local_monitors);
Expand Down Expand Up @@ -2004,6 +2014,8 @@ _PyMonitoring_SetLocalEvents(PyCodeObject *code, int tool_id, _PyMonitoringEvent
goto done;
}

code->_co_monitoring->tool_versions[tool_id] = interp->monitoring_tool_versions[tool_id];

_Py_LocalMonitors *local = &code->_co_monitoring->local_monitors;
uint32_t existing_events = get_local_events(local, tool_id);
if (existing_events == events) {
Expand Down Expand Up @@ -2036,6 +2048,43 @@ _PyMonitoring_GetLocalEvents(PyCodeObject *code, int tool_id, _PyMonitoringEvent
return 0;
}

int _PyMonitoring_ClearToolId(int tool_id)
{
assert(0 <= tool_id && tool_id < PY_MONITORING_TOOL_IDS);
PyInterpreterState *interp = _PyInterpreterState_GET();

for (int i = 0; i < _PY_MONITORING_EVENTS; i++) {
PyObject *func = _PyMonitoring_RegisterCallback(tool_id, i, NULL);
if (func != NULL) {
Py_DECREF(func);
}
}

if (_PyMonitoring_SetEvents(tool_id, 0) < 0) {
return -1;
}

_PyEval_StopTheWorld(interp);
uint32_t version = global_version(interp) + MONITORING_VERSION_INCREMENT;
if (version == 0) {
PyErr_Format(PyExc_OverflowError, "events set too many times");
_PyEval_StartTheWorld(interp);
return -1;
}

// monitoring_tool_versions[tool_id] is set to latest global version here to
// 1. invalidate local events on all existing code objects
// 2. be ready for the next call to set local events
interp->monitoring_tool_versions[tool_id] = version;

// Set the new global version so all the code objects can refresh the
// instrumentation.
set_global_version(_PyThreadState_GET(), version);
int res = instrument_all_executing_code_objects(interp);
_PyEval_StartTheWorld(interp);
return res;
}

/*[clinic input]
module monitoring
[clinic start generated code]*/
Expand Down Expand Up @@ -2083,6 +2132,33 @@ monitoring_use_tool_id_impl(PyObject *module, int tool_id, PyObject *name)
Py_RETURN_NONE;
}

/*[clinic input]
monitoring.clear_tool_id
tool_id: int
/
[clinic start generated code]*/

static PyObject *
monitoring_clear_tool_id_impl(PyObject *module, int tool_id)
/*[clinic end generated code: output=04defc23470b1be7 input=af643d6648a66163]*/
{
if (check_valid_tool(tool_id)) {
return NULL;
}

PyInterpreterState *interp = _PyInterpreterState_GET();

if (interp->monitoring_tool_names[tool_id] != NULL) {
if (_PyMonitoring_ClearToolId(tool_id) < 0) {
return NULL;
}
}

Py_RETURN_NONE;
}

/*[clinic input]
monitoring.free_tool_id
Expand All @@ -2099,6 +2175,13 @@ monitoring_free_tool_id_impl(PyObject *module, int tool_id)
return NULL;
}
PyInterpreterState *interp = _PyInterpreterState_GET();

if (interp->monitoring_tool_names[tool_id] != NULL) {
if (_PyMonitoring_ClearToolId(tool_id) < 0) {
return NULL;
}
}

Py_CLEAR(interp->monitoring_tool_names[tool_id]);
Py_RETURN_NONE;
}
Expand Down Expand Up @@ -2376,6 +2459,7 @@ monitoring__all_events_impl(PyObject *module)

static PyMethodDef methods[] = {
MONITORING_USE_TOOL_ID_METHODDEF
MONITORING_CLEAR_TOOL_ID_METHODDEF
MONITORING_FREE_TOOL_ID_METHODDEF
MONITORING_GET_TOOL_METHODDEF
MONITORING_REGISTER_CALLBACK_METHODDEF
Expand Down
1 change: 1 addition & 0 deletions Python/pystate.c
Original file line number Diff line number Diff line change
Expand Up @@ -654,6 +654,7 @@ init_interpreter(PyInterpreterState *interp,
interp->monitoring_callables[t][e] = NULL;

}
interp->monitoring_tool_versions[t] = 0;
}
interp->sys_profile_initialized = false;
interp->sys_trace_initialized = false;
Expand Down