Skip to content

Uncertainty estimation of the state of charge for a Lithium-ion battery (Panasonic CGR-17500) calculated using the direct voltage mapping method based on the discharge curve of the battery.

License

Notifications You must be signed in to change notification settings

signaloid/Signaloid-Demo-Batteries-StateOfChargeEstimation

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

7 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

[Add to signaloid.io] [Add to signaloid.io]

State of Charge Estimation in Batteries

The State of Charge (SoC) of a battery expresses its remaining capacity as a percentage of its total capacity. Accurately estimating the State of Charge is crucial in battery-powered systems. For example, an autonomous drone must have that information to decide when to return for recharging.

The State of Charge is usually estimated from a combination of battery voltage and system current. Measurement uncertainty and production process variability lead to uncertainties in the state of charge estimate. Systems that accurately track this uncertainty can make better decisions, as illustrated below.

drone example

Directly Mapping Voltage to State of Charge

As the battery is discharged its output voltage decreases. The figure below shows the discharge curve of a Panasonic CGR-17500 cell. The steep start, flat middle, and steep end is characteristic of the Li-Ion chemistry. In the absence of measurement uncertainty, the state of charge can be determined exactly from the voltage1. Unfortunately, the estimate is sensitive to noise. Even small uncertainties in voltage can translate to large uncertainties in state of charge, as the animation below shows. A blanket safety margin won't accurately reflect the true uncertainty as the animation below also shows.

uncertainty amplification

Getting started

The correct way to clone this repository to get the submodules is:

	git clone --recursive git@github.com:signaloid/Signaloid-Demo-Batteries-StateOfChargeEstimation.git

If you forgot to clone with --recursive and end up with empty submodule directories, you can remedy this with:

	git submodule update --init

Running the application on the Signaloid Cloud Developer Platform

To run this application on the Signaloid Cloud Developer Platform, you need a Signaloid account. You can sign up for a Signaloid account using this link.

Once you have a Signaloid account, you can click the "add to signaloid.io" button at the top of this README.md to connect this repository to the Signaloid Cloud Developer Platform and run the application.

Running the application locally

Apart from using Signaloid's Cloud Compute Platform, you can compile and run this application locally. Local execution is essentially a native Monte Carlo implementation, that uses GNU Scientific Library2 to generate samples for the different input distributions. In this mode the application stores the generated output samples, in a file called data.out. The first line of data.out contains the execution time of the Monte Carlo implementation in microseconds (μs), and each next line contains a floating-point value corresponding to an output sample value.

In order to compile and run this application in the native Monte Carlo mode:

  1. Install dependencies (e.g., on Linux):
sudo apt-get install libgsl-dev libgslcblas0
  1. Compile natively (e.g., on Linux):
cd src/
gcc -I. -I/opt/local/include main.c batt.c utilities.c common.c uxhw.c -L/opt/local/lib -o native-exe -lgsl -lgslcblas -lm
  1. Run the application in the MonteCarlo mode, using (-M) command-line option:
./native-exe -M 10000

The above program runs 10000 Monte Carlo iterations. 3. See the output samples generated by the local Monte Carlo execution:

cat data.out

Inputs

The only input to the state of charge estimation application is the measured voltage provided with the command-line flag -V. If the value provided with -V is particle valued (i.e., not distributional), then the output of the application will also be particle valued. However, with Signaloid microarchitectures it is also possible to input distributional values using what is called Ux-Strings, which are string encodings of representations of distributions used by Signaloid microarchitectures. With such a distributional value provided with the command-line flag -V, the output of the application will also be a distributional value.

Outputs

The output of the state of charge estimation application is the state of charge estimate of the Panasonic CGR-17500 battery cell for the input measured voltage.

Following is an example output, using Signaloid's C0Pro-XL+ core, for the default input:

Example output plot

Usage

Example: Battery state estimation routines - Signaloid version

Usage: Valid command-line arguments are:
        [-o, --output <Path to output CSV file : str>] (Specify the output file.)
        [-M, --multiple-executions <Number of executions : int> (Default: 1)] (Repeated execute kernel for benchmarking.)
        [-T, --time] (Timing mode: Times and prints the timing of the kernel execution.)
        [-b, --benchmarking] (Benchmarking mode: Generate outputs in format for benchmarking.)
        [-j, --json] (Print output in JSON format.)
        [-h, --help] (Display this help message.)
        [-V, --measuredVoltage <Measured voltage of battery : double> (Default: Gauss(3.70, 0.01))] (Set input measured voltage.)




Footnotes

  1. Ignoring the effects of temperature, discharge rate, number of cycles etc.

  2. GNU Scientific Library.

About

Uncertainty estimation of the state of charge for a Lithium-ion battery (Panasonic CGR-17500) calculated using the direct voltage mapping method based on the discharge curve of the battery.

Topics

Resources

License

Stars

Watchers

Forks

Contributors 3

  •  
  •  
  •